Intrastromal Corneal Ring Segment Implantation (Keraring 355°) in Patients with Central Keratoconus: 6-Month Follow-Up
المؤلفون المشاركون
Serahati, Sara
Jadidi, Khosrow
Mosavi, Seyed Aliasghar
Nejat, Farhad
Naderi, Mostafa
Janani, Leila
المصدر
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-01-05
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
We evaluate the efficacy and safety of Keraring 355° intrastromal corneal ring segment (ICRS) implantation aided by PocketMaker microkeratome for the correction of keratoconus.
Patients underwent ICRS insertion using mechanical dissection with PocketMaker microkeratome and completed 6 months of follow-up.
Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, topographic findings, safety, efficacy index, and adverse events were reported for six months postoperatively.
We evaluated 15 eyes of 15 patients (12 men) with a mean age of 28.87 ± 6.94 years (range 21–49 years).
At final postoperative examination, there was a statistically significant reduction in the spherical equivalent refractive error compared to preoperative measurements (−5.46 ± 1.52 to −2.01 ± 1.63 D, P < 0.001 ).
Mean preoperative UCVA (logMAR) before implantation was 0.79 ± 0.48, and postoperative UCVA was 0.28 ± 0.15, P = 0.001 .
Mean preoperative BSCVA (logMAR) before implantation was 0.36 ± 0.21; at final follow-up examination BSCVA was 0.18 ± 0.9, P = 0.009 .
Mean K decreased from 48.33 to 43.31 D, P < 0.001 .
All patients were satisfied with ICRS implantation; 86.7% were moderately to very happy with the results.
No intraoperative or postoperative complications were demonstrated.
This preliminary study shows that ICRS (Keraring 355°) implantation is an efficient, cost-effective, and minimally invasive procedure for improving visual acuity in nipple type keratoconic corneas.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Jadidi, Khosrow& Mosavi, Seyed Aliasghar& Nejat, Farhad& Naderi, Mostafa& Janani, Leila& Serahati, Sara. 2015. Intrastromal Corneal Ring Segment Implantation (Keraring 355°) in Patients with Central Keratoconus: 6-Month Follow-Up. Journal of Ophthalmology،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1069884
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Jadidi, Khosrow…[et al.]. Intrastromal Corneal Ring Segment Implantation (Keraring 355°) in Patients with Central Keratoconus: 6-Month Follow-Up. Journal of Ophthalmology No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1069884
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Jadidi, Khosrow& Mosavi, Seyed Aliasghar& Nejat, Farhad& Naderi, Mostafa& Janani, Leila& Serahati, Sara. Intrastromal Corneal Ring Segment Implantation (Keraring 355°) in Patients with Central Keratoconus: 6-Month Follow-Up. Journal of Ophthalmology. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1069884
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1069884
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر