MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data
المؤلف
المصدر
Science and Technology of Nuclear Installations
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-07-31
دولة النشر
مصر
عدد الصفحات
7
الملخص EN
Gamma-ray measurements in various research fields require efficient detectors.
One of these research fields is mass attenuation coefficients of different materials.
Apart from experimental studies, the Monte Carlo (MC) method has become one of the most popular tools in detector studies.
An NaI(Tl) detector has been modeled, and, for a validation study of the modeled NaI(Tl) detector, the absolute efficiency of 3 × 3 inch cylindrical NaI(Tl) detector has been calculated by using the general purpose Monte Carlo code MCNP-X (version 2.4.0) and compared with previous studies in literature in the range of 661–2620 keV.
In the present work, the applicability of MCNP-X Monte Carlo code for mass attenuation of concrete sample material as building material at photon energies 59.5 keV, 80 keV, 356 keV, 661.6 keV, 1173.2 keV, and 1332.5 keV has been tested by using validated NaI(Tl) detector.
The mass attenuation coefficients of concrete sample have been calculated.
The calculated results agreed well with experimental and some other theoretical results.
The results specify that this process can be followed to determine the data on the attenuation of gamma-rays with other required energies in other materials or in new complex materials.
It can be concluded that data from Monte Carlo is a strong tool not only for efficiency studies but also for mass attenuation coefficients calculations.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Tekin, Huseyin Ozan. 2016. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data. Science and Technology of Nuclear Installations،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1118584
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Tekin, Huseyin Ozan. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data. Science and Technology of Nuclear Installations No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1118584
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Tekin, Huseyin Ozan. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data. Science and Technology of Nuclear Installations. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1118584
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1118584
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر