Evaluation of RealStar® Alpha Herpesvirus PCR Kit for Detection of HSV-1, HSV-2, and VZV in Clinical Specimens

المؤلفون المشاركون

Yip, Cyril C. Y.
Sridhar, Siddharth
Leung, Kit-Hang
Cheng, Andrew K. W.
Chan, Kwok-Hung
Chan, Jasper F. W.
Cheng, Vincent C. C.
Yuen, K. Y.

المصدر

BioMed Research International

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-10-09

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Several commercial PCR kits are available for detection of herpes simplex virus (HSV) and varicella zoster virus (VZV), but the test performance of one CE-marked in vitro diagnostic kit—RealStar® alpha Herpesvirus PCR Kit—has not been well studied.

This study evaluated the performance of RealStar® alpha Herpesvirus PCR Kit 1.0 on the LightCycler® 480 Instrument II for detection and differentiation of HSV-1, HSV-2, and VZV in human clinical specimens.

We evaluated the analytical sensitivity of the RealStar® and in-house multiplex real-time PCR assays using serial dilutions of nucleic acids extracted from clinical specimens.

The analytical sensitivity of the RealStar® assay was 10, 32, and 100 copies/reaction for HSV-1, HSV-2, and VZV, respectively, which was slightly higher than that of the in-house multiplex real-time PCR assay.

Reproducibility of the cycle threshold (Cp) values for each viral target was satisfactory with the intra- and interassay coefficient of variation values below 5% for both assays.

One-hundred and fifty-three clinical specimens and 15 proficiency testing samples were used to evaluate the diagnostic performance of RealStar® alpha Herpesvirus PCR Kit against the in-house multiplex real-time PCR assay.

The RealStar® assay showed 100% sensitivity and specificity when compared to the in-house assay.

Cp values of the RealStar® and in-house assays showed excellent correlation.

RealStar® alpha Herpesvirus PCR is a sensitive, specific, and reliable assay for the detection of HSV-1, HSV-2, and VZV, with less extensive verification requirements compared to a laboratory developed assay.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yip, Cyril C. Y.& Sridhar, Siddharth& Leung, Kit-Hang& Cheng, Andrew K. W.& Chan, Kwok-Hung& Chan, Jasper F. W.…[et al.]. 2019. Evaluation of RealStar® Alpha Herpesvirus PCR Kit for Detection of HSV-1, HSV-2, and VZV in Clinical Specimens. BioMed Research International،Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1126193

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yip, Cyril C. Y.…[et al.]. Evaluation of RealStar® Alpha Herpesvirus PCR Kit for Detection of HSV-1, HSV-2, and VZV in Clinical Specimens. BioMed Research International No. 2019 (2019), pp.1-6.
https://search.emarefa.net/detail/BIM-1126193

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yip, Cyril C. Y.& Sridhar, Siddharth& Leung, Kit-Hang& Cheng, Andrew K. W.& Chan, Kwok-Hung& Chan, Jasper F. W.…[et al.]. Evaluation of RealStar® Alpha Herpesvirus PCR Kit for Detection of HSV-1, HSV-2, and VZV in Clinical Specimens. BioMed Research International. 2019. Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1126193

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1126193