Purpose.
Emergency physicians are at risk for infection during invasive procedures, and the respirators can reduce this risk.
This study aimed to determine whether endotracheal intubation using direct laryngoscopes affected protection performances of respirators.
Methods.
A randomized crossover study of 24 emergency physicians was performed.
We performed quantitative fit tests using respirators (cup type, fold type without a valve, and fold type with a valve) before and during intubation.
The primary outcome was respirators’ fit factors (FF), and secondary outcomes were acceptable protection (percentage of scores above 100 FF [FF%]).
Results.
24 pieces of data were analyzed.
Compared to fold-type respirator without a valve, FF and FF% values were lower when participants wore a cup-type respirator (200 FF [200-200] versus 200 FF [102.75–200], 100% [78.61–100] versus 74.16% [36.1–98.9]; all P<0.05) or fold-type respirator with a valve (200 FF [200-200] versus 142.5 FF [63.50–200], 100% [76.10–100] versus 62.50% [8.13–100]; all P<0.05).
There were no significant differences in intubation time and success rate according to respirator types.
Conclusions.
Motion during endotracheal intubation using direct laryngoscopes influenced the protective performance of some respirators.
Therefore, emergency physicians should identify and wear respirators that provide the best personalized fit for intended tasks.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lim, Tae Ho& Lee, Sanghyun& Oh, Jaehoon& Kang, Hyunggoo& Ahn, Chiwon& Song, Yeongtak…[et al.]. 2017. Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial. BioMed Research International،Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1138674
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lim, Tae Ho…[et al.]. Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial. BioMed Research International No. 2017 (2017), pp.1-8.
https://search.emarefa.net/detail/BIM-1138674
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lim, Tae Ho& Lee, Sanghyun& Oh, Jaehoon& Kang, Hyunggoo& Ahn, Chiwon& Song, Yeongtak…[et al.]. Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1138674
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1138674
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر