True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes
المؤلفون المشاركون
Smirnov, A.
Yasinskii, V. M.
Filimonenko, D. S.
Rostova, E.
Dietler, G.
Sekatskii, S. K.
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-22
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
تكنولوجيا المعلومات وعلم الحاسوب
الملخص EN
In scanning near-field optical microscopy, the most popular probes are made of sharpened glass fiber attached to a quartz tuning fork (TF) and exploiting the shear force-based feedback.
The use of tapping mode feedback could be preferable.
Such an approach can be realized, for example, using bent fiber probes.
Detailed analysis of fiber vibration modes shows that realization of truly tapping mode of the probe dithering requires an extreme caution.
In case of using the second resonance mode, probes vibrate mostly in shear force mode unless the bending radius is rather small (ca.
0.3 mm) and the probe’s tip is short.
Otherwise, the shear force character of the dithering persists.
Probes having these characteristics were prepared by irradiation of a tapered etched glass fiber with a CW CO2 laser.
These probes were attached to the TF in double resonance conditions which enables achieving significant quality factor (4000–6000) of the TF + probe system (Cherkun et al., 2006).
We also show that, to achieve a truly tapping character, dithering, short, and not exceeding 3 mm lengths of a freestanding part of bent fiber probe beam should also be used in the case of nonresonant excitation.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Smirnov, A.& Yasinskii, V. M.& Filimonenko, D. S.& Rostova, E.& Dietler, G.& Sekatskii, S. K.. 2018. True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes. Scanning،Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1212892
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Smirnov, A.…[et al.]. True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes. Scanning No. 2018 (2018), pp.1-9.
https://search.emarefa.net/detail/BIM-1212892
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Smirnov, A.& Yasinskii, V. M.& Filimonenko, D. S.& Rostova, E.& Dietler, G.& Sekatskii, S. K.. True Tapping Mode Scanning Near-Field Optical Microscopy with Bent Glass Fiber Probes. Scanning. 2018. Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1212892
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1212892
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر