Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM
المؤلفون المشاركون
Cao, Jianzhu
Xie, Feng
Zhang, Liguo
Lou, Mengqi
Tong, Jiejuan
Liu, Weirong
Wang, Yong
المصدر
Science and Technology of Nuclear Installations
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-11-01
دولة النشر
مصر
عدد الصفحات
12
الملخص EN
After the successful construction and operation experience of the 10 MW high-temperature gas-cooled reactor (HTR-10), a high-temperature gas-cooled pebble-bed modular (HTR-PM) demonstration plant is under construction in Shidao Bay, Rongcheng City, Shandong province, China.
An online gross γ monitoring instrument has been designed and placed at the exit of the helium purification system (HPS) of HTR-PM and is used to detect the activity concentration in the primary circuit after purification.
The source terms in the primary loop of HTR-PM and the helium purification process were described.
The detailed configuration of the gross γ monitoring instrument was presented in detail.
The Monte Carlo method was used to simulate the detection efficiency of the monitoring system.
Since the actual source terms in the primary loop of HTR-PM may be different than the current design values, a sensitivity analysis of the detection efficiency was implemented based on different relative proportions of the nuclides.
The accuracy and resolution of the NaI(Tl) detector were discussed as well.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lou, Mengqi& Zhang, Liguo& Xie, Feng& Cao, Jianzhu& Tong, Jiejuan& Liu, Weirong…[et al.]. 2018. Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM. Science and Technology of Nuclear Installations،Vol. 2018, no. 2018, pp.1-12.
https://search.emarefa.net/detail/BIM-1214969
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lou, Mengqi…[et al.]. Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM. Science and Technology of Nuclear Installations No. 2018 (2018), pp.1-12.
https://search.emarefa.net/detail/BIM-1214969
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lou, Mengqi& Zhang, Liguo& Xie, Feng& Cao, Jianzhu& Tong, Jiejuan& Liu, Weirong…[et al.]. Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM. Science and Technology of Nuclear Installations. 2018. Vol. 2018, no. 2018, pp.1-12.
https://search.emarefa.net/detail/BIM-1214969
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1214969
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر