تأثير حجم الفضاءات بين الأعمدة على استجابة لهياكل الخرسانية المسلحة للحمل الانفجاري

العناوين الأخرى

Spacing size effect between columns on the blast load response of reinforced concrete frame

المؤلفون المشاركون

الأعرجي، رياض مؤيد مال الله
كشمولة، سفيان يونس أحمد

المصدر

مجلة جامعة بابل للعلوم الهندسية

العدد

المجلد 28، العدد 1 (30 يونيو/حزيران 2020)، ص ص. 108-119، 12ص.

الناشر

جامعة بابل

تاريخ النشر

2020-06-30

دولة النشر

العراق

عدد الصفحات

12

التخصصات الرئيسية

الهندسة المدنية

الملخص AR

The present research focuses on studying the effect of the geometric shape of the redistribution of spaces between the internal columns on the behavior of reinforced concrete structural frames exposed to explosive load, and the evaluation of the damage caused by that load on the structures.

The eight-story reinforced concrete structure and three bays are designed according to the American Code ACI-14.

SAP2000 (V.20) was used for analysis, design and study of the elastic – plastic structural response under the blast loads, through several variables, including the maximum lateral and plastic displacements, the number and condition of the formed plastic hinges, and index damage.

The two-dimensional structural element was represented by a three-degree of freedom (beam-column) model, where the interaction between the axial force and the moment was used as a yield surface to follow the transition from elastic to plastic behavior for the columns, while the yield moment was defined as a yield criterion for the same behavior according to the principle of accumulated plasticity (Plastic Hinge) at the end of element.

The uniformity in the column spacing, for a geometrical shape considerations, having a clear effect on reducing the deformations and plastic displacements of the structure and reducing the damage index with respect to the energy dissipated after the structural response.

As a result, the distance between the mass and stiffness centers of the structural members affect the response of frame, the least distance between these two centers results in least damage to the structural elements compared to other symmetrical cases.

الملخص EN

The present research focuses on studying the effect of the geometric shape of the redistribution of spaces between the internal columns on the behavior of reinforced concrete structural frames exposed to explosive load, and the evaluation of the damage caused by that load on the structures.

The eight-story reinforced concrete structure and three bays are designed according to the American Code ACI-14.

SAP2000 (V.20) was used for analysis, design and study of the elastic-plastic structural response under the blast loads, through several variables, including the maximum lateral and plastic displacements, the number and condition of the formed plastic hinges, and index damage.

The two-dimensional structural element was represented by a three-degree of freedom (beam-column) model, where the interaction between the axial force and the moment was used as a yield surface to follow the transition from elastic to plastic behavior for the columns, while the yield moment was defined as a yield criterion for the same behavior according to the principle of accumulated plasticity (Plastic Hinge) at the end of element.

The uniformity in the column spacing, for a geometrical shape considerations, having a clear effect on reducing the deformations and plastic displacements of the structure and reducing the damage index with respect to the energy dissipated after the structural response.

As a result, the distance between the mass and stiffness centers of the structural members affect the response of frame, the least distance between these two centers results in least damage to the structural elements compared to other symmetrical cases.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

كشمولة، سفيان يونس أحمد والأعرجي، رياض مؤيد مال الله. 2020. تأثير حجم الفضاءات بين الأعمدة على استجابة لهياكل الخرسانية المسلحة للحمل الانفجاري. مجلة جامعة بابل للعلوم الهندسية،مج. 28، ع. 1، ص ص. 108-119.
https://search.emarefa.net/detail/BIM-1253987

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

كشمولة، سفيان يونس أحمد والأعرجي، رياض مؤيد مال الله. تأثير حجم الفضاءات بين الأعمدة على استجابة لهياكل الخرسانية المسلحة للحمل الانفجاري. مجلة جامعة بابل للعلوم الهندسية مج. 28، ع. 1 (2020)، ص ص. 108-119.
https://search.emarefa.net/detail/BIM-1253987

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

كشمولة، سفيان يونس أحمد والأعرجي، رياض مؤيد مال الله. تأثير حجم الفضاءات بين الأعمدة على استجابة لهياكل الخرسانية المسلحة للحمل الانفجاري. مجلة جامعة بابل للعلوم الهندسية. 2020. مج. 28، ع. 1، ص ص. 108-119.
https://search.emarefa.net/detail/BIM-1253987

نوع البيانات

مقالات

لغة النص

العربية

الملاحظات

يتضمن مراجع ببليوجرافية : ص. 118-119

رقم السجل

BIM-1253987