Simultaneous Determination of Copper, Lead, and Cadmium at Hexagonal Mesoporous Silica Immobilized Quercetin Modified Carbon Paste Electrode

المؤلفون المشاركون

Liu, Zhen
Sun, Danzi
Zhou, Changli
Xia, Fangquan
Zhang, Xin
Dong, Yanmin

المصدر

Journal of Automated Methods and Management in Chemistry

العدد

المجلد 2010، العدد 2010 (31 ديسمبر/كانون الأول 2010)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2010-04-27

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الكيمياء

الملخص EN

A new method was developed for simultaneous determination of copper, lead, and cadmium, based on their voltammetric response at a carbon paste electrode modified with hexagonal mesoporous silica (HMS) immobilized quercetin (HMS-Qu/CPE).

Compared with quercetin modified carbon paste electrode (Qu/CPE) and quercetin ionic liquid modified carbon paste electrode (Qu-IL/CPE), the HMS-Qu/CPE exhibited improved selectivity and high sensitivity toward the detection of copper, lead, and cadmium.

The properties of the HMS-Qu/CPE in 0.1 M HCOONa-HCl buffer solution (pH4.7) were investigated by adsorptive stripping voltammetry (ASV) and electrochemical impedance spectroscopy (EIS).

The electrochemical behavior of copper, lead, and cadmium at the modified electrodes and factors affecting the preconcentration procedures were also investigated.

Detection limits of 5.0, 0.8, 1.0 nM for copper, lead, and cadmium were obtained, respectively.

The method is simple, fast, sensitive, and selective, and is successfully applied to soil sample.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Xia, Fangquan& Zhang, Xin& Zhou, Changli& Sun, Danzi& Dong, Yanmin& Liu, Zhen. 2010. Simultaneous Determination of Copper, Lead, and Cadmium at Hexagonal Mesoporous Silica Immobilized Quercetin Modified Carbon Paste Electrode. Journal of Automated Methods and Management in Chemistry،Vol. 2010, no. 2010, pp.1-6.
https://search.emarefa.net/detail/BIM-501037

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Xia, Fangquan…[et al.]. Simultaneous Determination of Copper, Lead, and Cadmium at Hexagonal Mesoporous Silica Immobilized Quercetin Modified Carbon Paste Electrode. Journal of Automated Methods and Management in Chemistry No. 2010 (2010), pp.1-6.
https://search.emarefa.net/detail/BIM-501037

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Xia, Fangquan& Zhang, Xin& Zhou, Changli& Sun, Danzi& Dong, Yanmin& Liu, Zhen. Simultaneous Determination of Copper, Lead, and Cadmium at Hexagonal Mesoporous Silica Immobilized Quercetin Modified Carbon Paste Electrode. Journal of Automated Methods and Management in Chemistry. 2010. Vol. 2010, no. 2010, pp.1-6.
https://search.emarefa.net/detail/BIM-501037

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-501037