Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
المؤلفون المشاركون
Du, Zhiping
Wang, Junwei
Xue, Wei
Wang, Wanxu
المصدر
International Journal of Electrochemistry
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-11-22
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
The construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper.
The electrode is based on hexadecyl trimethyl ammonium bromide-Sodium dodecylsulfate (CTA+DS−) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of −58 ± 0.9 mV/decade in a 5.0 × 10−6 to 2.5 × 10−3 mol L−1 concentration range and a limit of detection of 2.9 × 10−6 mol L−1.
The electrode can be used for 3 months without showing significant changes in the value of slope or working range.
Also the electrode has wide pH range of application and short response time.
The electrode shows a selective response to SDS and a poor response to common inorganic anions.
The selective sequence found was SDS > HCO3 − > CH3COO− > Cl− > I− > NO3 −≈ Br− > F− > CO3 2− > C6H5O7 3− > C2O4 2− > SO4 2− > C4H4O6 2− > SO3 2− > PO4 3−.
The potentiometric selectivity coefficients determined are indicating that common anions would not interfere in the SDS determination.
The electrode has been utilized as an end point indicator electrode for potentiometric titration involving hyamine as titrant.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Wang, Junwei& Du, Zhiping& Wang, Wanxu& Xue, Wei. 2011. Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore. International Journal of Electrochemistry،Vol. 2011, no. 2011, pp.1-7.
https://search.emarefa.net/detail/BIM-511458
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Wang, Junwei…[et al.]. Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore. International Journal of Electrochemistry No. 2011 (2011), pp.1-7.
https://search.emarefa.net/detail/BIM-511458
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Wang, Junwei& Du, Zhiping& Wang, Wanxu& Xue, Wei. Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore. International Journal of Electrochemistry. 2011. Vol. 2011, no. 2011, pp.1-7.
https://search.emarefa.net/detail/BIM-511458
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-511458
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر