Separation of bovine serum albumin using chromatographical column : parameters and simulation

Other Title(s)

فصل مصل الذم الحيواني باستخذام عمود الكروماتوكراف : المعاملات و المحاكات

Joint Authors

Ali, Ahmad Jawad
Huwayl, Cecilia Khushaba
Ilyas, Samar Najah

Source

Iraqi Journal of Chemical and Petroleum Engineering

Issue

Vol. 11, Issue 1 (31 Mar. 2010), pp.1-9, 9 p.

Publisher

University of Baghdad College of Engineering

Publication Date

2010-03-31

Country of Publication

Iraq

No. of Pages

9

Main Subjects

Zoology
Chemistry

Topics

Abstract AR

كروماتوكراف الصلب-السائل لمصل الدم الحيواني (Bovine Serum Albumin) على مادة (Diethyleaminoethiel-cellulose) أو (DEAE-cellulose) قد تم اشتغاله عمليا.

لدراسة تأثير التغير البتركيز الداخل إلى العمود (0.125, 0.25, 0.5, and 1 mg/ml) بثبوت معدل الجريان الحجمي (1 ml / min) ثم دراسة تأثير التغير بمعدل الجريان الحجمي (1, 3, 5, and 10 ml/min) بثبوت التركيز الداخل (0.125 mg / ml).

العمل التجريبي قد تم باستخدام عمود زجاجي نصف طول قطره الداخلي (1.5 سم) و طوله (50 سم)، محشو بمادة DEAE-cellulose (diethylaminoethyl-cellulose) بطول (7 سم).

السائل الداخل يدخل إلى العمود باستخدام مضخة من نوع peristaltic pump، و تركيز السائل الخارج تم قياسه باستخدام جهاز الأشعة فوق البنفسجية UV-spectrophotometer بدرجة حرارة (30°C) بطول موجي (280 nm).

كان تركيز السائل الداخل (0.125 mg / ml ) الأفضل لأنه يعطي break-through point قليلة مع break-through curve منبسط.

هذا التركيز (0.125 mg / ml) استخدم في تطبيق تجارب أخرى لمعدلات جريان متلفة.

هنا، معدلات الجريان الحجمي التي هي أقل من (3 ml / min) تكون تقريبا متطابقة لنفس الظروف التشغيلية.

لهذا من الأفضل لهذا النظام ان يعمل على معدل جريان حجمي قليل يتراوح بين (1-3 ml / min) بنفس الظروف.

موديلات التوازن المتشتت للكروماتوغراف السائل-الصلب لخليط ثنائي المربوط بعلاقة لانكمور ايزوثيرم قد استخدم في اشتقاق الموديل الرياضي لهذا العمل.

الموديل الناتج قد حل عدديا باستخدام برنامج MATLAB v.6.5.

Abstract EN

A liquid-solid chromatography of bovine serum albumin (BSA) on (diethylaminoethyl-cellulose) DEAE-cellulose adsorbent is worked experimentally, to study the effect of changing the influent concentration of (0.125, 0.25, 0.5, and 1 mg / ml) at constant volumetric flow rate Q=1ml / min.

And the effect of changing the volumetric flow rate (1, 3, 5, and 10 ml / min) at constant influent concentration of Co=0.125mg / ml.

By using a glass column of (1.5cm) I.D and (50cm) length, packed with adsorbent of DEAE-cellulose of height (7cm).

The influent is introduced in to the column using peristaltic pump and the effluent concentration is investigated using UV-spectrophotometer at 30oC and 280nm wavelength.

A spread (steeper) break-through curve is gained at lean feed concentration of 0.125mg/ml, while the flow rate greater than (3ml / min) is almost the same.

So it is butter to work at low volumetric flow rate between (1-3) ml/min.

The equilibrium-dispersion model of liquid-solid chromatography for a binary mixture, related with Langmuir isotherm correlation is used in the modeling of this work.

The resulting model is solved numerically by using MATLAB V.6.5 program.

American Psychological Association (APA)

Huwayl, Cecilia Khushaba& Ali, Ahmad Jawad& Ilyas, Samar Najah. 2010. Separation of bovine serum albumin using chromatographical column : parameters and simulation. Iraqi Journal of Chemical and Petroleum Engineering،Vol. 11, no. 1, pp.1-9.
https://search.emarefa.net/detail/BIM-287249

Modern Language Association (MLA)

Huwayl, Cecilia Khushaba…[et al.]. Separation of bovine serum albumin using chromatographical column : parameters and simulation. Iraqi Journal of Chemical and Petroleum Engineering Vol. 11, no. 1 (Mar. 2010), pp.1-9.
https://search.emarefa.net/detail/BIM-287249

American Medical Association (AMA)

Huwayl, Cecilia Khushaba& Ali, Ahmad Jawad& Ilyas, Samar Najah. Separation of bovine serum albumin using chromatographical column : parameters and simulation. Iraqi Journal of Chemical and Petroleum Engineering. 2010. Vol. 11, no. 1, pp.1-9.
https://search.emarefa.net/detail/BIM-287249

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 8-9

Record ID