Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o)‎ and scattered light effect at two opposite position (2N90o )‎ using Ayah 4SW-3D-T180 -2N90 -Solar - CFI Analyser

Other Title(s)

تقدير الأتينولول في مستحضراته الدوائية باستخدام تحليل الحقن الجرياني المستمر عن طريق قياس التعكريه (T180o)‎ و تأثير استطارة الضوء عند اتجاهين متعاكسين (2N90o)‎ باستخدام المحلل Ayah 4SW-3D-T180-2N90-Solar-CFI

Joint Authors

al-Awwadi, Nagham Shakir Turki
Khudayr, Ahmad Fadil

Source

Iraqi Journal of Science

Issue

Vol. 55, Issue 1 (31 Mar. 2014), pp.12-26, 15 p.

Publisher

University of Baghdad College of Science

Publication Date

2014-03-31

Country of Publication

Iraq

No. of Pages

15

Main Subjects

Chemistry

Topics

Abstract AR

استحدثت طريقة بسيطة و سريعة لتقدير أتينولول بشكله النقي أو على هيئة مستحضرات دوائية من خلال اقتران تقنية الحقن الجرياني المستمر مع قياس التعكرية و الاستطارة.

تستند الطريقة على تكوين راسب أبيض لمزدوج أيوني بين الاتنولول و حامض مولبدات الفسفوريك في الوسط المائي, تم قياس التعكرية للراسب عن طريق توهين الضوء الساقط و كذلك استطارته عند زاوية قائمه و باتجاهين متعاكسين +90 و -90.

تم دراسة المتغيرات الكيميائية و الفيزيائية للحصول على الظروف المثلى لتعين الأتينولول، مدى الخطية للأتينولول بين (0.1-11) مللي مول.

لتر-1مع معامل الارتباط 0.9938=r و حدود الكشف (L.

O.

D) 0.05ملي مول.

لتر-1 (3SB) (3 = S/N) و ل 13 = n, الانحراف القياسي المئوي أقل من 3% لتركيز 7 مللي مول.

لتر-1 أتينولول ل (n = 7).

طبقت هذه الطريقة بنجاح لتعين الأتينولول في ثلاثة عقاقير دوائية.

أجريت مقارنة بين الطريقة المستحدثة مع الطريقة التقليدية للقياس الطيفي (مطيافية الأشعة فوق البنفسجية عند طول موجي 274 نانومتر) باستخدام طريقة الإضافات القياسية و ذلك من خلال استخدام اختبار - t و لوحظ عدم وجود فرق جوهري عند 0.05= و حدود ثقة 95% بين الطريقتين و بالإمكان استخدام الطريقة المستحدثة كطريقة بديلة لتقدير أتينولول, بالإضافة إلى المقارنة بين القيمة الرسمية و القيمة المحسوبة لكلا الطريقتين.

Abstract EN

A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o).

The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium.

The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured.

Chemical and physical parameters were investigated.

The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r = 0.9938, lower limit of detection (LOD) 0.05 mmol.L-1(3SB)(S/N=3) for n = 13 and the relative standard deviation for 7 mmol.L-1 Atenolol solution is lower than 3 % (n = 7).

The method was applied successfully for the determination of atenolol in three pharmaceutical drugs.

A comparisons were made between the newly developed method of analysis with the classical method ( uv-spectrophotometry at wave length 274nm) of analysis using the standard addition method via the use of t- test.

It shows that there was no significant difference at α = 0.05(95 % confidence) between the two methods.

Therefore the newly developed method can be accepted as an alternative method for the analysis of Atenolol, in addition to comparison between the official value and the calculated value for both methods.

American Psychological Association (APA)

al-Awwadi, Nagham Shakir Turki& Khudayr, Ahmad Fadil. 2014. Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o ) using Ayah 4SW-3D-T180 -2N90 -Solar - CFI Analyser. Iraqi Journal of Science،Vol. 55, no. 1, pp.12-26.
https://search.emarefa.net/detail/BIM-373250

Modern Language Association (MLA)

al-Awwadi, Nagham Shakir Turki& Khudayr, Ahmad Fadil. Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o ) using Ayah 4SW-3D-T180 -2N90 -Solar - CFI Analyser. Iraqi Journal of Science Vol. 55, no. 1 (2014), pp.12-26.
https://search.emarefa.net/detail/BIM-373250

American Medical Association (AMA)

al-Awwadi, Nagham Shakir Turki& Khudayr, Ahmad Fadil. Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o ) using Ayah 4SW-3D-T180 -2N90 -Solar - CFI Analyser. Iraqi Journal of Science. 2014. Vol. 55, no. 1, pp.12-26.
https://search.emarefa.net/detail/BIM-373250

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 23-26

Record ID

BIM-373250