New approach for an on-line turbidmetric determination of cadmium (II) in different river water via the use of a homemade ayah 6SX1-T-2D solar-continuous flow injection analyzer
Other Title(s)
نمط جديد لقياس التعكرية الأني أيون الكادميوم في مختلف مياه الأنهر من خلال محلل جديد مصنع محليا للحقن الجرياني المستمر (Ayah 6SX1-T-2D Solar)
Joint Authors
al-Awwadi, Nagham Shakir Turki
Yasin, Umar Iyad
Source
Issue
Vol. 55, Issue 4A (31 Dec. 2014), pp.1402-1414, 13 p.
Publisher
University of Baghdad College of Science
Publication Date
2014-12-31
Country of Publication
Iraq
No. of Pages
13
Main Subjects
Topics
Abstract AR
تم تطوير طريقه تحليلية جديدة, تميزت بالسرعة و الحساسية لتقدير أيون الكادميوم الثنائي في المحاليل المائية لثلاث نماذج عشوائية الاختيار من مياه الأنهر و لمواقع مختلفة عن طريق قياس التعكرية بوساطة محلل الحقن الجرياني المستمر Ayah 6SX1-T-2D Solar.
استندت الطريقة على تكوين راسب أبيض مصفر للمعقد Cd3 [Fe (CN)] 2 بوساطة التفاعل المباشر لأيون الكادميوم (II) مع بوتاسيوم سداسي سيانيد الحديديك K3 [Fe (CN) 6] في وسط مائي.
تم قياس التعكرية عن طريق انعكاس الضوء المسلط و المصطدم بسطوح دقائق الراسب بزاوية 180-0 °.
تم دراسة كافة المتغيرات الفيزياوية و الكيميائية.
العلاقة الخطية لمنحنى المعايرة لأيون الكادميوم (II) تمتد من 12-0.5 مللي مول.
لتر1- بمعامل ارتباط 0.9951 = r.
حدود الكشف كانت = 25.29نانوغرام / أنموذج من التخفيف التدريجي لأقل تركيز في منحنى المعايرة مع انحراف قياسي نسبي مئوي RSD % أقل من 1.5 % لتركيز 8 مللي مول.
لتر1- (n = 5) من أيون الكادميوم (II).
طبقت الطريقة بنجاح لتقدير أيون الكادميوم (II) في ثلاث نماذج لمياه النهر.
أجريت مقارنة بين الطريقة المستحدثة للتحليل و الطريقة التقليدية لقياس التعكرية باستخدام منحنى الإضافات القياسية و بوساطة المعالجة بتحليل المتغيرات (ANOVA).
لوحظ أنه يوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95 %، حيث تم الحصول على 0.05 > sig.
على هذا الأساس بالإمكان قبول الطريقة الجديدة كطريقة تحليلية بديلة.
Abstract EN
A newly developed analytical method characterized by its speed and sensitivity for the determination of cadmium (II) in aqueous solution in three randomly chosen samples from river water at different locations via turbidimetric measurement by Ayah 6SX1-T-2D Solar-CFI analyser.
The method is based on the formation of yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium.
Turbidity was measured via the reflection of incident light that collides on the surfaces precipitated particles at 0-180o.
Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with correlation coefficient r = 0.9951.
The limit of detection 25.29 ng / sample from the step wise dilution for the minimum concentration in the linear dynamic range of the calibration graph with RSD % lower than 1.5 % for 8 mmol.L-1 (n = 5) concentration of cadmium (II).
The method was applied successfully for the determination of cadmium (II) in three river samples.
A comparison was made between the proposed method of analysis with the classical method (HANNA instrument for turbidity measurement) using the standard additions method via the use of ANOVAtreatments.
It was noticed that there is a significant difference at α = 0.05 between the two methods at level < 0.05 was obtained.
On that basis the new method can be accepted as an alternative analytical method.
American Psychological Association (APA)
al-Awwadi, Nagham Shakir Turki& Yasin, Umar Iyad. 2014. New approach for an on-line turbidmetric determination of cadmium (II) in different river water via the use of a homemade ayah 6SX1-T-2D solar-continuous flow injection analyzer. Iraqi Journal of Science،Vol. 55, no. 4A, pp.1402-1414.
https://search.emarefa.net/detail/BIM-516146
Modern Language Association (MLA)
al-Awwadi, Nagham Shakir Turki& Yasin, Umar Iyad. New approach for an on-line turbidmetric determination of cadmium (II) in different river water via the use of a homemade ayah 6SX1-T-2D solar-continuous flow injection analyzer. Iraqi Journal of Science Vol. 55, no. 4A (2014), pp.1402-1414.
https://search.emarefa.net/detail/BIM-516146