A novel semi automated on-line determination of oxonium ion via precipitation reaction using a new mode of attenuated measurement of incident light (0-180o) by ayah 5SX4-ST-5D solar CFI analyser
Other Title(s)
تقدير نبيل اني شبه تلقائي لأيون الأوكسونيوم عن طريق تفاعل الترسيب باستخدام نمط جديد لقياس توهين الضوء الساقط بزاوية (180°-0) بوساطة AYAH 5SX4-ST-5D solar CFI analyser
Joint Authors
al-Hashimi, Isam Muhammad Ali Shakir
al-Jabburi, Husayn Faris Abd al-Razzaq
Source
Issue
Vol. 55, Issue 4B (31 Dec. 2014), pp.1736-1750, 15 p.
Publisher
University of Baghdad College of Science
Publication Date
2014-12-31
Country of Publication
Iraq
No. of Pages
15
Main Subjects
Abstract AR
قدرت الحوامض القوية عن طريق تفاعل الترسيب و المعتمد على التفاعل بين أيون النحاس الثنائي و المحمل على مبادل أيوني حامضي قوي و بوتاسيوم سداسي ثايوسيانات الحديد (II).
قياس توهين الضوء المسلط بزاوية (°180 – 0) و المعتمد على تكوين راسب Cu2 [Fe (CN)6] يتم عن طريق محلل الحقن الجرياني المستمر و المصنع محلياً AYAH 5SX4 – ST – 5D solar CFI analyser.
تم اختيار الظروف الفضلى 0.005 مول.لتر1- [Fe(CN)6]-4 و سرعة الجريان 2.4 مل.دقيقة1-.
حجم الأنموذج المحقن 204 مايكروليتر, زمن حقن الأنموذج 64 ثانية و بالإضافة إلى 1.6 فولت و هي شدة الضوء الساقط.
منحنى معايرة بحدود 0.2 – 0.005 مول.لتر1- لكل من HCL, HNO3, HCIO4 بالإضافة إلى H2SO4 مع نسبة خطية (r2 %) تمتد من 97 – 96 % بالإضافة إلى حدود الكشف (LOD) و المستندة على التخفيف التدريجي لأقل تركيز في منحنى المعايرة 73.19 ملغم لأنموذج HCL, 64.273 مكغم لـ HNO3, 102.26 مكغم لـ HCIO4 بالإضافة إلى 0.01 مكغم لـ HCIO4 بالإضافة إلى 0.01 مكغم لـ H2SO4.
تم الحصول على تكرارية (RSD %) أقل من 1.12.
و قد تم مقارنة الطريقة المقترحة مع الطريقة الكلاسيكية لكل من الحوامض المتوفرة (H2SO4, HCL).
Abstract EN
Strong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II).
The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser.
Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1, sample volume 204 μL, sample purge time of 64 seconds was chosen, and 1.6 V for light intensity.
A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 μg for HCl, 64.273 μg for HNO3, 102.26 μg for HCLO4, and 0.01 μg for H2SO4.
Repeatability (RSD %) less than 1.12 was obtained.
The proposed was compared well with standard method.
FTU method for available acid in commercial (HCl, H2SO4).
American Psychological Association (APA)
al-Hashimi, Isam Muhammad Ali Shakir& al-Jabburi, Husayn Faris Abd al-Razzaq. 2014. A novel semi automated on-line determination of oxonium ion via precipitation reaction using a new mode of attenuated measurement of incident light (0-180o) by ayah 5SX4-ST-5D solar CFI analyser. Iraqi Journal of Science،Vol. 55, no. 4B, pp.1736-1750.
https://search.emarefa.net/detail/BIM-526994
Modern Language Association (MLA)
al-Hashimi, Isam Muhammad Ali Shakir& al-Jabburi, Husayn Faris Abd al-Razzaq. A novel semi automated on-line determination of oxonium ion via precipitation reaction using a new mode of attenuated measurement of incident light (0-180o) by ayah 5SX4-ST-5D solar CFI analyser. Iraqi Journal of Science Vol. 55, no. 4B (2014), pp.1736-1750.
https://search.emarefa.net/detail/BIM-526994
American Medical Association (AMA)
al-Hashimi, Isam Muhammad Ali Shakir& al-Jabburi, Husayn Faris Abd al-Razzaq. A novel semi automated on-line determination of oxonium ion via precipitation reaction using a new mode of attenuated measurement of incident light (0-180o) by ayah 5SX4-ST-5D solar CFI analyser. Iraqi Journal of Science. 2014. Vol. 55, no. 4B, pp.1736-1750.
https://search.emarefa.net/detail/BIM-526994
Data Type
Journal Articles
Language
English
Notes
Text in English ; abstracts in English and Arabic.
Record ID
BIM-526994