![](/images/graphics-bg.png)
Fire-resistance of styroferrocement sandwich panels
Joint Authors
Abd al-Khidr, Muhammad Rauf
Abd Allah, Ata Shaykh Karim
Source
Engineering and Technology Journal
Issue
Vol. 34, Issue 6A (30 Jun. 2016), pp.1150-1160, 11 p.
Publisher
Publication Date
2016-06-30
Country of Publication
Iraq
No. of Pages
11
Main Subjects
Topics
Abstract EN
This paper investigates the effect of fire on ferrocement sandwich panels.
The experimental program consisted of fabricating and testing nine panels (400X400x30 mm in dimensions).
The variables were type and number of mesh and Styrophoam content.
A special arrangement was designed to create the effect of fire on panels.
Test results showed that ferrocement panels have an endurance of fire when compared to control panels which may provide a desired protection to fire.
In-spite-of wire mesh cracks, in plane cracks occurred when more volume fraction of mesh included.
Whereas Styrophoam content affected the number of in-plane cracks.
Plastic wire mesh had no significant effect on the wire mesh-induced cracks.
American Psychological Association (APA)
Abd al-Khidr, Muhammad Rauf& Abd Allah, Ata Shaykh Karim. 2016. Fire-resistance of styroferrocement sandwich panels. Engineering and Technology Journal،Vol. 34, no. 6A, pp.1150-1160.
https://search.emarefa.net/detail/BIM-696887
Modern Language Association (MLA)
Abd al-Khidr, Muhammad Rauf& Abd Allah, Ata Shaykh Karim. Fire-resistance of styroferrocement sandwich panels. Engineering and Technology Journal Vol. 34, no. 6A (2016), pp.1150-1160.
https://search.emarefa.net/detail/BIM-696887
American Medical Association (AMA)
Abd al-Khidr, Muhammad Rauf& Abd Allah, Ata Shaykh Karim. Fire-resistance of styroferrocement sandwich panels. Engineering and Technology Journal. 2016. Vol. 34, no. 6A, pp.1150-1160.
https://search.emarefa.net/detail/BIM-696887
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 1159-1160
Record ID