Experimental study of model piled raft foundation embedded within partially saturated cohesionless soils

Other Title(s)

دراسة عملية و تحليلية لنماذج أسس حصيرية مدعمه بالركائز مغروزه في تربه حبيبيه مشبعه جزئيا

Joint Authors

Kandu, Ahmad Khayr Allah Abd al-Aziz
al-Wakil, Sad Fayiq Abbas
al-Qaysi, Mahmud Rashid

Source

Journal of Engineering and Sustainable Development

Issue

Vol. 22, Issue 3 (31 May. 2018), pp.62-75, 14 p.

Publisher

al-Mustansyriah University College of Engineering

Publication Date

2018-05-31

Country of Publication

Iraq

No. of Pages

14

Main Subjects

Civil Engineering

Abstract EN

This paper presents an experimental study conducted on model piled rafts in partially saturated sandy soil.

the aim of the experimental program is to study the effect of matric suction on the load carrying capacity of piled rafts embedded within partially saturated sandy soil .the influence of number of piles are presented and discussed in this study.

the piled raft is arranged in different configurations of piles (single, double and triple piled raft with spacing 3.5d c/c) with the same area ratio (raft area to the cross section area of piles) to avoid different contact pressure area and to show the effect of different piles number and its group action.

the influence of matric suction (i.e., capillary stresses) in partially saturated zone is typically not taken into account in the conventional design of both shallow and deep foundations so that the present research study the determination and contribution of matric suction towards the load carrying capacity of piled raft.

the experimental work consist of 3 models of footing "single piled raft (8.3 x 5) cm, double piled (16.6 x 5) cm and triple piled raft (25 x 5) cm".

all these models are loaded and tested under both of fully saturated condition (i.e., matric suction equals to 0kpa) and unsaturated conditions (i.e., matric suction value equals to 6kpa , 8kpa and 10kpa), which are achieved by predetermined lowering of water table.

the relationship between matric suction and depth of ground water table was measured in suction profile set by using three tensiometers (irrometer).

the soil, water characteristic curve (SWCC) estimated by applying fitting methods through the program (soilvision).

the results of experimental work demonstrate that the load carrying capacity of piled raft increases with increasing all values of matric suction as the number of piles supporting the raft increases.

and the matric suction has a significant influence on the load carrying capacity of all tested models.

the increasing value of the ultimate bearing capacity for single, double and triple piled raft under unsaturated conditions is approximately (2.1-4.47), (2-4.44) and (1.5-3.54) times higher than that at saturated condition respectively

American Psychological Association (APA)

al-Qaysi, Mahmud Rashid& al-Wakil, Sad Fayiq Abbas& Kandu, Ahmad Khayr Allah Abd al-Aziz. 2018. Experimental study of model piled raft foundation embedded within partially saturated cohesionless soils. Journal of Engineering and Sustainable Development،Vol. 22, no. 3, pp.62-75.
https://search.emarefa.net/detail/BIM-908764

Modern Language Association (MLA)

al-Qaysi, Mahmud Rashid…[et al.]. Experimental study of model piled raft foundation embedded within partially saturated cohesionless soils. Journal of Engineering and Sustainable Development Vol. 22, no. 3 (May. 2018), pp.62-75.
https://search.emarefa.net/detail/BIM-908764

American Medical Association (AMA)

al-Qaysi, Mahmud Rashid& al-Wakil, Sad Fayiq Abbas& Kandu, Ahmad Khayr Allah Abd al-Aziz. Experimental study of model piled raft foundation embedded within partially saturated cohesionless soils. Journal of Engineering and Sustainable Development. 2018. Vol. 22, no. 3, pp.62-75.
https://search.emarefa.net/detail/BIM-908764

Data Type

Journal Articles

Language

English

Record ID

BIM-908764