Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

Joint Authors

Morales-Fernández, L.
Garcia-Feijoo, J.
Fernández-Pérez, Cristina
Arriola-Villalobos, Pedro
Martinez-de-la-Casa, Jose Maria
Diaz-Valle, David

Source

Journal of Ophthalmology

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-11-01

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Purpose.

To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT).

Methods.

A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract.

Patients underwent cataract surgery along with the implant of two iStent inject devices.

Outcome measures were intraocular pressure (IOP), topical hypotensive medications required, and best-corrected visual acuity (BCVA).

Results.

20 patients were enrolled.

Mean follow-up was 47.4±18.46 months.

Mean baseline IOP was 19.95±3.71 mmHg with medication and 26±3.11 mmHg after washout.

Mean end-follow-up IOP was 16.25±1.99 mmHg, representing an IOP decrease of 36.92%, 9.74±3.14 mmHg (P<0.001), from baseline washout IOP.

The mean number of medications was significantly reduced from 1.3±0.66 to 0.75±0.79 (P=0.017).

45% of patients were medication-free by the end of follow-up.

Mean logMAR BCVA improved significantly from 0.42±0.16 to 0.18±0.16 (P<0.001).

No complications of surgery were observed.

Conclusion.

The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT) and cataract.

American Psychological Association (APA)

Arriola-Villalobos, Pedro& Martinez-de-la-Casa, Jose Maria& Diaz-Valle, David& Morales-Fernández, L.& Fernández-Pérez, Cristina& Garcia-Feijoo, J.. 2016. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109810

Modern Language Association (MLA)

Arriola-Villalobos, Pedro…[et al.]. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study. Journal of Ophthalmology No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1109810

American Medical Association (AMA)

Arriola-Villalobos, Pedro& Martinez-de-la-Casa, Jose Maria& Diaz-Valle, David& Morales-Fernández, L.& Fernández-Pérez, Cristina& Garcia-Feijoo, J.. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109810

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1109810