Single- and Bicomponent Analyses of T2⁎ Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones)‎ Magnetic Resonance Imaging

Joint Authors

Zhu, Yanchun
Liu, Jin
Nazaran, Amin
Ma, Yajun
Chen, Haimei
Li, Shaolin
Zhou, Quan
Zhao, Yinghua
Du, Jiang

Source

BioMed Research International

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-9, 9 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-02-18

Country of Publication

Egypt

No. of Pages

9

Main Subjects

Medicine

Abstract EN

The collagen density is not detected in the patellar tendon (PT), posterior cruciate ligament (PCL), and anterior cruciate ligament (ACL) in clinic.

We assess the technical feasibility of three-dimension multiecho fat saturated ultrashort echo time cones (3D FS-UTE-Cones) acquisitions for single- and bicomponent T2⁎ analysis of bound and free water pools in PT, PCL, and ACL in clinic.

The knees of five healthy volunteers and six knee joint samples from cadavers were scanned via 3D multiecho FS-UTE-Cones acquisitions on a clinical scanner.

Single-component fitting of T2⁎M and bicomponent fitting of short T2⁎ (T2⁎S), long T2⁎ (T2⁎L), short T2⁎ fraction (Frac_S), and long T2⁎ fraction (Frac_L) were performed within tendons and ligaments.

Our results showed that biexponential fitting was superior to single-exponential fitting in PT, PCL, and ACL.

For knee joint samples, there was no statistical difference among all data in PT, PCL, and ACL.

For volunteers, all parameters of bicomponent fitting were statistically different across PT, PCL, and ACL, except for T2⁎S, T2⁎L, and T2⁎M resulting in flawed measurements due to the magic angle effect.

3D multiecho FS-UTE-Cones acquisition allows high resolution T2⁎ mapping in PT, PCL, and ACL of keen joint samples and PT and PCL of volunteers.

The T2⁎ values and their fractions can be characterized by bicomponent T2⁎ analysis that is superior to single-component T2⁎ analysis, except for ACL of volunteers.

American Psychological Association (APA)

Liu, Jin& Nazaran, Amin& Ma, Yajun& Chen, Haimei& Zhu, Yanchun& Du, Jiang…[et al.]. 2019. Single- and Bicomponent Analyses of T2⁎ Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones) Magnetic Resonance Imaging. BioMed Research International،Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1128014

Modern Language Association (MLA)

Liu, Jin…[et al.]. Single- and Bicomponent Analyses of T2⁎ Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones) Magnetic Resonance Imaging. BioMed Research International No. 2019 (2019), pp.1-9.
https://search.emarefa.net/detail/BIM-1128014

American Medical Association (AMA)

Liu, Jin& Nazaran, Amin& Ma, Yajun& Chen, Haimei& Zhu, Yanchun& Du, Jiang…[et al.]. Single- and Bicomponent Analyses of T2⁎ Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones) Magnetic Resonance Imaging. BioMed Research International. 2019. Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1128014

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1128014