Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy
Joint Authors
Florian, Löcherbach
Grimsehl, P.
Sauer, A.
Wyler, S.
Kwiatkowski, M.
Source
Issue
Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-3, 3 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2018-10-30
Country of Publication
Egypt
No. of Pages
3
Main Subjects
Abstract EN
We would like to present the case of a 64-year-old woman who underwent ureterorenoscopy and suffered an iatrogenic ureteral lesion due to an accidental intubation of the left ureter with a Foley-Catheter during the procedure.
A Double-J-Stent was implanted into the damaged ureter, and 6 weeks later it fully recovered.
To our knowledge there are few similar cases described in the literature with none of those having happened during ureterorenoscopy so far.
American Psychological Association (APA)
Florian, Löcherbach& Grimsehl, P.& Sauer, A.& Wyler, S.& Kwiatkowski, M.. 2018. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology،Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1151563
Modern Language Association (MLA)
Florian, Löcherbach…[et al.]. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology No. 2018 (2018), pp.1-3.
https://search.emarefa.net/detail/BIM-1151563
American Medical Association (AMA)
Florian, Löcherbach& Grimsehl, P.& Sauer, A.& Wyler, S.& Kwiatkowski, M.. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology. 2018. Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1151563
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1151563