Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns

Joint Authors

Oldak, David
García, Gabriela
Gonzalez, Estela E.
Aillon, Enver
Falcon, Juan C.
Ayala, Ernesto
Oldak, Bernardo

Source

International Journal of Pediatrics

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-01-01

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Medicine

Abstract EN

Background.

Newborn hyperbilirubinemia is considered a worldwide health problem that demands medical evaluation.

Noninvasive transcutaneous bilirubin (TcB) has been used as a screening method with different devices but there has not been any evaluation of reproducibility of the same brand devices.

The BiliCare™ system is evaluated to demonstrate consistency between measurements with four different devices.

Methods.

336 TcB measurements were obtained with four BiliCare™ devices in 21 Mexican icteric newborns with a mean postnatal age of 44.1 hours of life and 38 weeks of gestation (33–41).

Two measurements were taken in the same ear alternatively at the scaphoid fossa with each device.

TcB values were compared between devices.

Validity was compared with total serum bilirubin (TB).

Results.

intraclass correlation coefficient demonstrates a minimum limit in the study of 0.945 and maximum of 0.988 with the same device.

Correlations with serum and between devices gave results above 0.932.

Conclusions.

BiliCare™ transcutaneous bilirubin measurement instrument has very good intra- and interdevice reproducibility; also correlation of TcS with serum bilirubin gave statistically the same results.

American Psychological Association (APA)

Oldak, David& García, Gabriela& Gonzalez, Estela E.& Aillon, Enver& Falcon, Juan C.& Ayala, Ernesto…[et al.]. 2019. Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns. International Journal of Pediatrics،Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1167571

Modern Language Association (MLA)

Oldak, David…[et al.]. Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns. International Journal of Pediatrics No. 2019 (2019), pp.1-5.
https://search.emarefa.net/detail/BIM-1167571

American Medical Association (AMA)

Oldak, David& García, Gabriela& Gonzalez, Estela E.& Aillon, Enver& Falcon, Juan C.& Ayala, Ernesto…[et al.]. Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns. International Journal of Pediatrics. 2019. Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1167571

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1167571