Highly Sensitive Amperometric α-Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites

Joint Authors

Peng, Gang
Yu, Yadong
Chen, Xiaojun
Huang, He

Source

International Journal of Analytical Chemistry

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-08-01

Country of Publication

Egypt

No. of Pages

10

Main Subjects

Chemistry
Science

Abstract EN

Herein, a rapid and highly sensitive amperometric biosensor for the detection of α-ketoglutarate (α-KG) was constructed via an electrochemical approach, in which the glutamate dehydrogenase (GLUD) was modified on the surface of reduced graphene oxide-gold nanoparticle composite (rGO-Aunano composite).

The rGO-Aunano composite was one-step electrodeposited onto glassy carbon electrode (GCE) surface and was characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and electrochemical techniques.

In addition, the rGO-Aunano/GCE was also found to electrocatalyze the oxidation of β-nicotinamide adenine dinucleotide (NADH) at the peak potential of 0.3 V, which was negatively shifted compared with that at bare GCE or Aunano/GCE, illustrating better catalytic performance of rGO-Aunano.

After the modification of GLUD, the GLUD/rGO-Aunano/GCE led to effective amperometric detection of α-KG through monitoring the NADH consumption and displayed a linear response in the range of 66.7 and 494.5 μM, with the detection limit of 9.2 μM.

Moreover, the prepared GLUD/rGO-Aunano/GCE was further evaluated to be highly selective and used to test α-KG in human serum samples.

The recovery and the RSD values were calculated in the range of 97.9–102.4% and 3.8–4.5%, respectively, showing a great prospect for its real application.

American Psychological Association (APA)

Peng, Gang& Yu, Yadong& Chen, Xiaojun& Huang, He. 2020. Highly Sensitive Amperometric α-Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites. International Journal of Analytical Chemistry،Vol. 2020, no. 2020, pp.1-10.
https://search.emarefa.net/detail/BIM-1167653

Modern Language Association (MLA)

Peng, Gang…[et al.]. Highly Sensitive Amperometric α-Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites. International Journal of Analytical Chemistry No. 2020 (2020), pp.1-10.
https://search.emarefa.net/detail/BIM-1167653

American Medical Association (AMA)

Peng, Gang& Yu, Yadong& Chen, Xiaojun& Huang, He. Highly Sensitive Amperometric α-Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites. International Journal of Analytical Chemistry. 2020. Vol. 2020, no. 2020, pp.1-10.
https://search.emarefa.net/detail/BIM-1167653

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1167653