التلوث الإشعاعي بالتدفق المغنطيسي و المجال الكهربائي الصادر من الأجهزة المنزلية و المكتبية

Other Title(s)

Radiative pollution by the electric and magnetic fluxes resulting from the domestic and offices appliances

Author

الراجحي، محمد عبد الله إبراهيم

Source

مجلة جامعة الملك عبد العزيز : العلوم

Issue

Vol. 20, Issue 2 (31 Dec. 2008), pp.23-39, 17 p.

Publisher

King Abdulaziz University Scientific Publishing Center

Publication Date

2008-12-31

Country of Publication

Saudi Arabia

No. of Pages

17

Main Subjects

Electronic engineering

Topics

Abstract AR

تعتبر الأجهزة المنزلية و المكتبية أهم مصادر الانبعاث الكهرومغنطيسي داخل المنازل و المكاتب، تم في هذا البحث قياس التدفق المغنطيسي ل (٤٩) جهازا، و قياس المجال الكهربائي لبعض الأجهزة لمسافات مختلفة، مبتعدين تدريجيا عن المصدر كل عشرة سنتمترات.

وكانت أعلى قراءة (٤٠٠٠٠٠ نانو تسلا) لمكينة حلاقه، إذا لم يكن يوجد مسافة بين المكينة و الكاشف، وعند الابتعاد مسافة (١٠ سم) تقل تدك القراءة إلى (٢٠٠٠٠٠ نانو تسلا)، و هي أعلى بكثير من حدود التعرض الموصى بها من قبل (ICNIRP).

كما أن أعلى قراءة مسجلة للمجال الكهربي كانت من مصابيح الفلوريسنت (١٥٠٠ فولت لكل متر)، إذا لم يكن يوجد مسافة ممن المصباح و الكاشف، و عند الابتعاد مسافة (١٠ سم) تقل تلك القراءة إلى (٣٠٠ فولت لكل متر)، و هي أقل بكثير من حدود التعرض الموصى بها من قبل (ICNIRP).

كما قورنت جميع القراءات (لبقية الأجهزة) لشدة المجال الكهربائي و المغنطيسي بحدود التعرض للمواصفات القياسية السويدية و الحدود المغادرة من المنظمة الدولية لحماية من الأشعة غير المؤينة ICNIRP.

يلي ذلك اقتراح تحديد المسافة الآمنة.

كما أشار البحث لضرورة قيام الهيئة السعودية للمواصفات و المقاييس بدورها في تحديد الحد الأعلى المسموح به للانبعاث الإشعاعي لكل جهاز على حده، بتطبيق خطوات هذا البحث، و بموجب تلك الحدود يمكن فرض التقيد بذلك على كل من المستوردين و المصنعين المحليين، حفاظا على بيئة صحية و درء لمخاطر إشعاعية محتملة.

Abstract EN

Abstract.

Domestic and office electric appliances are the main source of electromagnetic emissions within houses and offices.

In this study magnetic flux was estimated for 49 electric devices.

The electric field was also measured for a number of electric devices at different distances.

The variation in distance was 10 cm.

The maximum reading measured (400,000 nT) was for an electric shaving device; and it was 200,000 nT at 10 cm away from the same device.

It was much higher than limits recommended by ICNIRP.

The maximum reading for the electric field (1500 V/m) was from fluorescent lights.

At 10 cm away from these lights, the reading was 300 V/m, which is much less than limits recommended by ICNIRP.

The electric and magnetic fields of various electric devices were compared with both the Swedish standards and limits recommended by ICNIRP.

However, safe distances were recommended as well.

American Psychological Association (APA)

الراجحي، محمد عبد الله إبراهيم. 2008. التلوث الإشعاعي بالتدفق المغنطيسي و المجال الكهربائي الصادر من الأجهزة المنزلية و المكتبية. مجلة جامعة الملك عبد العزيز : العلوم،مج. 20، ع. 2، ص ص. 23-39.
https://search.emarefa.net/detail/BIM-330118

Modern Language Association (MLA)

الراجحي، محمد عبد الله إبراهيم. التلوث الإشعاعي بالتدفق المغنطيسي و المجال الكهربائي الصادر من الأجهزة المنزلية و المكتبية. مجلة جامعة الملك عبد العزيز : العلوم مج. 20، ع. 2 (2008)، ص ص. 23-39.
https://search.emarefa.net/detail/BIM-330118

American Medical Association (AMA)

الراجحي، محمد عبد الله إبراهيم. التلوث الإشعاعي بالتدفق المغنطيسي و المجال الكهربائي الصادر من الأجهزة المنزلية و المكتبية. مجلة جامعة الملك عبد العزيز : العلوم. 2008. مج. 20، ع. 2، ص ص. 23-39.
https://search.emarefa.net/detail/BIM-330118

Data Type

Journal Articles

Language

Arabic

Notes

يتضمن مراجع ببليوجرافية : ص. 34-38

Record ID

BIM-330118