Kiwi omnicup versus malmström's metal cup : comparing maternal and neonatal outcomes

Other Title(s)

مقارنة ناتح الحمل لدى الأمهات و حديثي الولادة عبر استخدام جهاز الشفط كيوي مقارنة بالمالمستروم

Author

Faqih, Wafa Muhammad Khalil

Source

Journal of King Abdulaziz University : Medical Sciences

Issue

Vol. 21, Issue 3 (30 Sep. 2014), pp.17-28, 12 p.

Publisher

King Abdulaziz University Scientific Publishing Center

Publication Date

2014-09-30

Country of Publication

Saudi Arabia

No. of Pages

12

Main Subjects

Medicine

Topics

Abstract AR

نظرا لإدخال جهاز سحب الجنين OmniCup إلى قسم النساء و الولادة عملنا على التقييم و المقارنة بين جهازي الـ Kiwi OmniCup و Malmström's ذا الرأس المعدني و ذلك في تأثيرهم و على ناتج الحمل لحديثي الولادة و على الحامل.

تم إجراء دراسة بأثر رجعي على جميع السيدات اللواتي ولدن ما بين تشرين الثاني ٢۰١۰ و نيسان ٢۰١٢م.

تم مقارنة الاختلاطات لحديثي الولادة و للأمهات كذلك.

تمت المقارنة بين أداء الجهازين Kiwi and metal cup و ذلك باستعمال فحص كاي سكوير.

تم إدراج ٢۰٢ سيدة من اللواتي خضعن للولادة بالجهازين (112 Kiwi OmniCup و 90 Malmström's metal cup)، فوجد أن وسطي تقييم أبغار و في الدقيقة الأولى و الخامسة كان أقل في حالة الولادة بالجهاز المعدني (بالتسلسل 0.08 و 0.07 P-value =) تسعة و ثلاثون حديث ولادة تم إدخالهم إلى قسم عناية الأطفال الفائقة، منهم ٣٨ خرجوا من المستشفى خلال أسبوع من تاريخ دخولهم، ٨ من ال ٣٩ تمت ولادتهم عن طريق أطباء استشاريين مقابل ٣١ تم ولادتهم من قبل أخصائيين (0.039 P-value =).

لم يتم تسجيل أية حالة وفاة للأم أو الجنين في هذه الدراسة.

تم استنتاج أن الجهاز الجديد Kiwi OmniCup هو خيار آمن مقارنة بالجهاز السابق Malmström's metal cup.

Abstract EN

With the introduction of the Kiwi OmniCup vacuum extractor at our institute, we aimed to evaluate and compare maternal and neonatal outcomes between the Kiwi OmniCup and the Malmström's metal cup in vacuum-assisted deliveries.

A retrospective study on all women who delivered by vacuum extraction between November 2010 and April 2012 was conducted.

We compared neonatal and maternal morbidity as well as the outcomes in the Kiwi and metal cup group by using chi-square tests.

202 women who had assisted-vaginal delivery (112 by Kiwi OmniCup and 90 by Malmström's metal cup) were included in this study.

The mean Apgar scores at one and five minutes were lower in the metal cup group (P-value = 0.07 and 0.08, respectively).

Thirty-nine newborns were admitted to the neonatal intensive care unit, of which 38 were discharged within one week.

Eight of the 39 neonates were delivered by consultants versus 31 delivered by registrars (P-value = 0.039).

There were no intrapartum or neonatal deaths.

In conclusion, the Kiwi OmniCup is a safe alternative to the currently available Malmström's metal cup for vacuum assisted delivery.

American Psychological Association (APA)

Faqih, Wafa Muhammad Khalil. 2014. Kiwi omnicup versus malmström's metal cup : comparing maternal and neonatal outcomes. Journal of King Abdulaziz University : Medical Sciences،Vol. 21, no. 3, pp.17-28.
https://search.emarefa.net/detail/BIM-556438

Modern Language Association (MLA)

Faqih, Wafa Muhammad Khalil. Kiwi omnicup versus malmström's metal cup : comparing maternal and neonatal outcomes. Journal of King Abdulaziz University : Medical Sciences Vol. 21, no. 3 (2014), pp.17-28.
https://search.emarefa.net/detail/BIM-556438

American Medical Association (AMA)

Faqih, Wafa Muhammad Khalil. Kiwi omnicup versus malmström's metal cup : comparing maternal and neonatal outcomes. Journal of King Abdulaziz University : Medical Sciences. 2014. Vol. 21, no. 3, pp.17-28.
https://search.emarefa.net/detail/BIM-556438

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 24-26

Record ID