Abstract EN
Background & Objective: The aim of this research is To report the results of covered Cheatham-Platinum (CP) stents implantation in patients with complex aortic coarctation Methods & Materials: Between January 2011 and march 2013, we implanted covered Cheatham-Platinum stents in 20 patients with complex aortic coarctation .
All procedures were performed under general anesthesia During follow-up, patients underwent physical examination, including blood pressure measurements, electrocardiogram, and echocardiography, at 1, 3, 6 and 12 months.
Magnetic resonance (MR) or CT angiography were performed at 3 and 12 months after the procedure.
Results: The stents used ranged from 23 to 44 mm in length.
The mean fluoroscopy and procedure times were 17 ± 8 and 83 ± 16 minutes, respectively.
After implantation, the gradient across the stenosis decreased significantly (pre stent: median value42 mm Hg [range 20-85 mm Hg] vs post stent: median value 0 mm Hg [range 0-4 mm Hg].
Vessel diameter increased from a median value of 5 mm (range 0-12) to a median value of 16 mm (range 11-26).., and on angiographic control, the stenoses had been relieved and the aneurysms completely excluded.
During a median follow-up of 12 months (1-21 months), the patients were stable without complications.
One patient developed intrastent restenosis(10 months after implantation) due to a significant endothelial proliferation and was successfully treated by high-pressure balloon angioplasty.
There were no deaths or serious complications Conclusion: Covered Cheatham-Platinum stents are safe and very effective tools for the treatment of complex aortic coarctation and gives good immediate results.
in equipped centers and experienced hands.
American Psychological Association (APA)
هيام محمود. 2015. توسيع تضيق برزخ الأبهر المعقد بالقثطرة القلبية باستعمال الشبكة المغطاة من نوع بلاتين تشيثام. مجلة جامعة دمشق للعلوم الطبية،مج. 31، ع. 2، ص ص. 17-25.
https://search.emarefa.net/detail/BIM-873159
Modern Language Association (MLA)
هيام محمود. توسيع تضيق برزخ الأبهر المعقد بالقثطرة القلبية باستعمال الشبكة المغطاة من نوع بلاتين تشيثام. مجلة جامعة دمشق للعلوم الطبية مج. 31، ع. 2 (2015)، ص ص. 17-25.
https://search.emarefa.net/detail/BIM-873159
American Medical Association (AMA)
هيام محمود. توسيع تضيق برزخ الأبهر المعقد بالقثطرة القلبية باستعمال الشبكة المغطاة من نوع بلاتين تشيثام. مجلة جامعة دمشق للعلوم الطبية. 2015. مج. 31، ع. 2، ص ص. 17-25.
https://search.emarefa.net/detail/BIM-873159
Data Type
Journal Articles
Language
Arabic
Notes
يتضمن مراجع ببليوجرافية : ص. 24-25
Record ID
BIM-873159