Purpose.
To compare the results of intraocular pressure (IOP) reduction by 3 treatment modalities, (a) glaucoma tube implants, (b) noncontact YAG laser cyclophotocoagulation (cycloYAG), and (c) contact transscleral diode laser cyclophotocoagulation (cyclodiode), in cases of advanced glaucoma refractory to alternative treatments.
Methods.
A consecutive group of 45 eyes that received cycloYAG were matched against two control groups of patients who had received tube surgery or cyclodiode, each control group having been derived from a database of patients.
Results.
Mean pretreatment IOP improved from 41.3, 38.6, and 32.0 mmHg for the tube, cycloYAG, and cyclodiode groups, respectively, to 16.4, 22.1, and 19.3 mmHg, respectively.
Treatment success was achieved in 78%, 69%, and 71% of the tube, cycloYAG, and cyclodiode groups, respectively.
Visual acuity deteriorated 2 or more Snellen lines in 16%, 7%, and 9% of the patients in the tube, cycloYAG, and cyclodiode groups, respectively.
Complications included retinal detachment, hypotony, and phthisis.
Conclusions.
All 3 methods provided acceptable IOP lowering in the short and medium term.
Control of IOP was best in patients receiving tube surgery.
Cyclodiode and cycloYAG treatments were similarly effective in lowering IOP.
Tube surgery was associated with a greater incidence of sight threatening complications.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Bloom, Philip A.& Clement, Colin I.& King, Anthony& Noureddin, Baha& Sharma, Kamal& Hitchings, Roger A.…[et al.]. 2013. A Comparison between Tube Surgery, ND:YAG Laser and Diode Laser Cyclophotocoagulation in the Management of Refractory Glaucoma. BioMed Research International،Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-1004131
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Bloom, Philip A.…[et al.]. A Comparison between Tube Surgery, ND:YAG Laser and Diode Laser Cyclophotocoagulation in the Management of Refractory Glaucoma. BioMed Research International No. 2013 (2013), pp.1-11.
https://search.emarefa.net/detail/BIM-1004131
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Bloom, Philip A.& Clement, Colin I.& King, Anthony& Noureddin, Baha& Sharma, Kamal& Hitchings, Roger A.…[et al.]. A Comparison between Tube Surgery, ND:YAG Laser and Diode Laser Cyclophotocoagulation in the Management of Refractory Glaucoma. BioMed Research International. 2013. Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-1004131
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1004131
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)