Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT

المؤلفون المشاركون

Li, Baojun
Li, Baohong
Luo, Jack
Tang, Peng
Mao, Jiandong
Wu, Xiaoye

المصدر

BioMed Research International

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-06-19

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

Dual-energy CT imaging tends to suffer from much lower signal-to-noise ratio than single-energy CT.

In this paper, we propose an improved anticorrelated noise reduction (ACNR) method without causing cross-contamination artifacts.

Methods.

The proposed algorithm diffuses both basis material density images (e.g., water and iodine) at the same time using a novel correlated diffusion algorithm.

The algorithm has been compared to the original ACNR algorithm in a contrast-enhanced, IRB-approved patient study.

Material density accuracy and noise reduction are quantitatively evaluated by the percent density error and the percent noise reduction.

Results.

Both algorithms have significantly reduced the noises of basis material density images in all cases.

The average percent noise reduction is 69.3% and 66.5% with the ACNR algorithm and the proposed algorithm, respectively.

However, the ACNR algorithm alters the original material density by an average of 13% (or 2.18 mg/cc) with a maximum of 58.7% (or 8.97 mg/cc) in this study.

This is evident in the water density images as massive cross-contaminations are seen in all five clinical cases.

On the contrary, the proposed algorithm only changes the mean density by 2.4% (or 0.69 mg/cc) with a maximum of 7.6% (or 1.31 mg/cc).

The cross-contamination artifacts are significantly minimized or absent with the proposed algorithm.

Conclusion.

The proposed algorithm can significantly reduce image noise present in basis material density images from dual-energy CT imaging, with minimized cross-contaminations compared to the ACNR algorithm.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Li, Baojun& Li, Baohong& Luo, Jack& Tang, Peng& Mao, Jiandong& Wu, Xiaoye. 2013. Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT. BioMed Research International،Vol. 2013, no. 2013, pp.1-8.
https://search.emarefa.net/detail/BIM-1004265

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Li, Baojun…[et al.]. Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT. BioMed Research International No. 2013 (2013), pp.1-8.
https://search.emarefa.net/detail/BIM-1004265

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Li, Baojun& Li, Baohong& Luo, Jack& Tang, Peng& Mao, Jiandong& Wu, Xiaoye. Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT. BioMed Research International. 2013. Vol. 2013, no. 2013, pp.1-8.
https://search.emarefa.net/detail/BIM-1004265

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1004265