الملخص EN
Purpose.
This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery.
The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery.
Method.
Two experiments that were noninvasive for both the patient and the surgeon were designed.
In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used.
The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery.
The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation.
Results and Conclusion.
Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments.
The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
López-Mir, F.& Naranjo, V.& Fuertes, J. J.& Alcañiz, M.& Bueno, J.& Pareja, E.. 2013. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment. BioMed Research International،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-1005054
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
López-Mir, F.…[et al.]. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment. BioMed Research International No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-1005054
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
López-Mir, F.& Naranjo, V.& Fuertes, J. J.& Alcañiz, M.& Bueno, J.& Pareja, E.. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment. BioMed Research International. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-1005054
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1005054
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر