CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

المؤلفون المشاركون

Schwiesau, Jens
Fritz, Bernhard
Kutzner, Ines
Bergmann, Georg
Grupp, Thomas M.

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-11-20

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material.

The addition of vitamin E to the bulk material is a potential way to reduce the aging processes.

This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty.

Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis.

After 5 million test cycles no structural failure of the gliding components was observed.

The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Schwiesau, Jens& Fritz, Bernhard& Kutzner, Ines& Bergmann, Georg& Grupp, Thomas M.. 2014. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities. BioMed Research International،Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-1016367

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Schwiesau, Jens…[et al.]. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities. BioMed Research International No. 2014 (2014), pp.1-9.
https://search.emarefa.net/detail/BIM-1016367

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Schwiesau, Jens& Fritz, Bernhard& Kutzner, Ines& Bergmann, Georg& Grupp, Thomas M.. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-1016367

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1016367