Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

المؤلفون المشاركون

Reinders, Jörn
Sonntag, Robert
Kretzer, Jan Philippe

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-09-09

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements.

High-conforming designs may provide additional stability for the joint.

This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design.

Methods.

Two simulator wear tests were performed on a high-conforming total knee replacement design.

In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated.

In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated.

Wear was determined gravimetrically and wear particles were analyzed.

Implant kinematics was recorded during simulation.

Results.

Significantly higher wear rates ( P ≤ 0.001 ) were observed for the unstable knee ( 14.58 ± 0.56 mg/106 cycles) compared to the stable knee ( 7.97   ±   0.87 mg/106 cycles).

A higher number of wear particles with only small differences in wear particle characteristics were observed.

Under unstable knee conditions, kinematics increased significantly for translations and rotations ( P ≤ 0.01 ).

This increase was mainly attributed to higher tibial posterior translation and internal rotations.

Conclusion.

Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design.

Due to the higher kinematics, increased wear was observed in this study.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Reinders, Jörn& Sonntag, Robert& Kretzer, Jan Philippe. 2014. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1016587

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Reinders, Jörn…[et al.]. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1016587

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Reinders, Jörn& Sonntag, Robert& Kretzer, Jan Philippe. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1016587

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1016587