Performance evaluation of poultry houses under different evaporative cooling systems
العناوين الأخرى
تقييم أداء مزارع الدواجن تحت أنظمة التبريد التبخيري المختلفة
المؤلفون المشاركون
al-Shadhili, Mahmud Abd al-Rahman
Wasfi, Kamal Ibrahim
Abd al-Ati, Ala Awni Ahmad
Abd al-Rahman, Sulayman Jad
المصدر
Zagazig Journal for Agricultural Researches
العدد
المجلد 47، العدد 4 (31 أغسطس/آب 2020)، ص ص. 999-1010، 12ص.
الناشر
تاريخ النشر
2020-08-31
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الموضوعات
الملخص EN
Poultry production occupied a major role in the agriculture industry worldwide.
Poultry housing design plays a vital role in determination of the internal climatic conditions for optimum health, growth and productive performance of the poultries.
The present investigation aimed to evaluate the performance of different evaporative cooling systems with environmental control of poultry houses.
The effect of two different evaporative cooling systems (direct and indirect) under three water flow rates of 2, 4 and 6 l/min.
m2 on poultry houses performance was evaluated in terms of temperature reduction, relative humidity, evaporative cooling efficiency, poultry weight, consumed energy and cost.
Experimental results revealed that using direct evaporative cooling system with 4 l/min.
m2 water flow rate and indirect evaporative cooling system with 2 l/min.
m2 water flow rate provided sufficient conditions of temperature reduction (9.59 and 7.28oC), relative humidity (63.88 and 61.21% ), cooling efficiency (75.67 and 83.67 % ), poultry weight (2.4 and 2.3 kg) and consumed energy (1.2 and 6 kW.
day) with net return (7.54 and 5.80 LE/kg), in that order.
Based on previously mentioned results, it is recommended to use direct evaporative cooling system for poultry houses as it minimizes both energy and cost requirements compared to the indirect evaporative cooling system, therefore it was found to be suitable for small rural farmers.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Abd al-Rahman, Sulayman Jad& al-Shadhili, Mahmud Abd al-Rahman& Wasfi, Kamal Ibrahim& Abd al-Ati, Ala Awni Ahmad. 2020. Performance evaluation of poultry houses under different evaporative cooling systems. Zagazig Journal for Agricultural Researches،Vol. 47, no. 4, pp.999-1010.
https://search.emarefa.net/detail/BIM-1023840
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Abd al-Rahman, Sulayman Jad…[et al.]. Performance evaluation of poultry houses under different evaporative cooling systems. Zagazig Journal for Agricultural Researches Vol. 47, no. 4 (2020), pp.999-1010.
https://search.emarefa.net/detail/BIM-1023840
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Abd al-Rahman, Sulayman Jad& al-Shadhili, Mahmud Abd al-Rahman& Wasfi, Kamal Ibrahim& Abd al-Ati, Ala Awni Ahmad. Performance evaluation of poultry houses under different evaporative cooling systems. Zagazig Journal for Agricultural Researches. 2020. Vol. 47, no. 4, pp.999-1010.
https://search.emarefa.net/detail/BIM-1023840
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
-
رقم السجل
BIM-1023840
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر