CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting

المؤلفون المشاركون

Guo, Hong
Chen, Yang
Li, Yinsheng
Hu, Yining
Yin, Xindao
Gu, Jianping
Toumoulin, Christine
Luo, Limin

المصدر

Mathematical Problems in Engineering

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-18، 18ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-08-14

دولة النشر

مصر

عدد الصفحات

18

التخصصات الرئيسية

هندسة مدنية

الملخص EN

The streak artifacts caused by metal implants degrade the image quality and limit the applications of CT imaging.

The standard method used to reduce these metallic artifacts often consists of interpolating the missing projection data but the result is often a loss of image quality with additional artifacts in the whole image.

This paper proposes a new strategy based on a three-stage process: (1) the application of a large-scale non local means filter (LS-NLM) to suppress the noise and enhance the original CT image, (2) the segmentation of metal artifacts and metallic objects using a mutual information maximized segmentation algorithm (MIMS), (3) a modified exemplar-based in-painting technique to restore the corrupted projection data in sinogram.

The final corrected image is then obtained by merging the segmented metallic object image with the filtered back-projection (FBP) reconstructed image from the in-painted sinogram.

Quantitative and qualitative experiments have been conducted on both a simulated phantom and clinical CT images and a comparative study has been led with Bal's algorithm that proposed a similar segmentation-based method.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Chen, Yang& Li, Yinsheng& Guo, Hong& Hu, Yining& Luo, Limin& Yin, Xindao…[et al.]. 2012. CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting. Mathematical Problems in Engineering،Vol. 2012, no. 2012, pp.1-18.
https://search.emarefa.net/detail/BIM-1029753

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Chen, Yang…[et al.]. CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting. Mathematical Problems in Engineering No. 2012 (2012), pp.1-18.
https://search.emarefa.net/detail/BIM-1029753

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Chen, Yang& Li, Yinsheng& Guo, Hong& Hu, Yining& Luo, Limin& Yin, Xindao…[et al.]. CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting. Mathematical Problems in Engineering. 2012. Vol. 2012, no. 2012, pp.1-18.
https://search.emarefa.net/detail/BIM-1029753

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1029753