Characterization of Sera with Discordant Results from Reverse Sequence Screening for Syphilis

المؤلفون المشاركون

Song, Eun Young
Lee, Kyunghoon
Park, Hyewon
Roh, Eun Youn
Shin, Sue
Park, Kyoung Un
Park, Myoung Hee

المصدر

BioMed Research International

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-12-26

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Reverse sequence screening for syphilis (RSSS) (screening with treponemal tests, followed by confirmation with nontreponemal tests) has been increasingly adopted.

CDC recommends confirmation of discordant results (reactive EIA/CIA and nonreactive nontreponemal test) with Treponema pallidum particle agglutination assay (TP-PA).

We characterized sera with discordant results from RSSS with Architect Syphilis TP CIA.

Among 15,713 screening tests using Architect Syphilis TP at Seoul National University Gangnam Center between October 2010 and May 2011, 260 (1.7%) showed reactive results.

Rapid plasma reagin (RPR) and TP-PA were performed on 153 available sera among them.

On sera with discordant results between Architect Syphilis TP and TP-PA, INNO-LIA Syphilis Score and FTA-ABS were performed.

Among 153 sera, RPR was nonreactive in 126 (82.4%).

Among them, TP-PA was positive in 103 (81.7%), indeterminate (±) in 7 (5.6%), and negative in 16 (12.7%).

Out of 16 CIA(+)/RPR(−)/TP-PA(−) sera, INNO-LIA Syphilis Score and/or FTA-ABS were negative on 14 sera.

Out of 7 CIA(+)/RPR(−)/TP-PA(±) sera, INNO-LIA Syphilis Score and FTA-ABS were positive/reactive in 6 sera.

RSSS with confirmation by TP-PA on sera with discordant results between Architect Syphilis TP and RPR effectively delineated those discordant results and could be successfully adopted for routine checkup for syphilis.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Lee, Kyunghoon& Park, Hyewon& Roh, Eun Youn& Shin, Sue& Park, Kyoung Un& Park, Myoung Hee…[et al.]. 2012. Characterization of Sera with Discordant Results from Reverse Sequence Screening for Syphilis. BioMed Research International،Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-1030265

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Lee, Kyunghoon…[et al.]. Characterization of Sera with Discordant Results from Reverse Sequence Screening for Syphilis. BioMed Research International No. 2013 (2013), pp.1-5.
https://search.emarefa.net/detail/BIM-1030265

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Lee, Kyunghoon& Park, Hyewon& Roh, Eun Youn& Shin, Sue& Park, Kyoung Un& Park, Myoung Hee…[et al.]. Characterization of Sera with Discordant Results from Reverse Sequence Screening for Syphilis. BioMed Research International. 2012. Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-1030265

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1030265