الملخص EN
The aim of this preliminary study is to investigate the correlation between clinical set-up at present used in the treatment of specific skin conditions and laser beam absorbed power in the tissue.
This study focused on the CO2 and Nd-Yag laser equipment used in the daily clinical practice in the Department of Dermatology of San Gallicano Institute in Rome.
Different types of tissue-equivalent material with various water and haemoglobin concentrations were tested to evaluate laser beam attenuation power.
In particular, thinly sliced pork loin, of uniform consistency and without fat, was selected for its high content of haemoglobin to mimic human tissues.
An optical power meter was used to measure the power or energy of a laser beam.
During measurements, the tissue equivalent phantoms were positioned on the detector head and the laser beam was orthogonally oriented.
The results of two experimental set-ups are reported here.
The dependence of residual power (W) as a function of ex vivo tissue thickness (mm) for different laser output powers was studied.
Data were fitted by a parametric logistic equation.
These preliminary data allow for more accurately determining the energy fraction released from lasers to the tissues in order to improve clinical outcomes.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Soriani, A.& D'Alessio, D.& Cattelan, V.& Cameli, N.& Mariano, M.& Ungania, S.…[et al.]. 2014. Physical and Dosimetric Optimization of Laser Equipment in Dermatology: A Preliminary Study. BioMed Research International،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-1034387
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Soriani, A.…[et al.]. Physical and Dosimetric Optimization of Laser Equipment in Dermatology: A Preliminary Study. BioMed Research International No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-1034387
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Soriani, A.& D'Alessio, D.& Cattelan, V.& Cameli, N.& Mariano, M.& Ungania, S.…[et al.]. Physical and Dosimetric Optimization of Laser Equipment in Dermatology: A Preliminary Study. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-1034387
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1034387
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر