The Analysis of Hand Movement Distinction Based on Relative Frequency Band Energy Method

المؤلفون المشاركون

Zhang, Yanyan
Teng, Chaolin
Sun, Zhongjiang
Wang, Jue
Wang, Gang

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-11-05

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

For the purpose of successfully developing a prosthetic control system, many attempts have been made to improve the classification accuracy of surface electromyographic (SEMG) signals.

Nevertheless, the effective feature extraction is still a paramount challenge for the classification of SEMG signals.

The relative frequency band energy (RFBE) method based on wavelet packet decomposition was proposed for the prosthetic pattern recognition of multichannel SEMG signals.

Firstly, the wavelet packet energy of SEMG signals in each subspace was calculated by using wavelet packet decomposition and the RFBE of each frequency band was obtained by the wavelet packet energy.

Then, the principal component analysis (PCA) and the Davies-Bouldin (DB) index were used to perform the feature selection.

Lastly, the support vector machine (SVM) was applied for the classification of SEMG signals.

Our results demonstrated that the RFBE approach was suitable for identifying different types of forearm movements.

By comparing with other classification methods, the proposed method achieved higher classification accuracy in terms of the classification of SEMG signals.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Zhang, Yanyan& Wang, Gang& Teng, Chaolin& Sun, Zhongjiang& Wang, Jue. 2014. The Analysis of Hand Movement Distinction Based on Relative Frequency Band Energy Method. BioMed Research International،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1034562

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Zhang, Yanyan…[et al.]. The Analysis of Hand Movement Distinction Based on Relative Frequency Band Energy Method. BioMed Research International No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-1034562

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Zhang, Yanyan& Wang, Gang& Teng, Chaolin& Sun, Zhongjiang& Wang, Jue. The Analysis of Hand Movement Distinction Based on Relative Frequency Band Energy Method. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1034562

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1034562