Determination of Urinary Creatinine in Washington State Residents via Liquid ChromatographyTandem Mass Spectrometry

المؤلفون المشاركون

West, Caroline E.
Rhodes, Blaine N.

المصدر

International Journal of Analytical Chemistry

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-12-30

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الكيمياء
علوم

الملخص EN

A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL).

50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS.

Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d3 were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d3).

The retention time for creatinine was 0.85 minutes.

The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L.

LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r = 0.9898 and R 2 = 0.9797 , ρ ≤ 0.0001 ).

The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

West, Caroline E.& Rhodes, Blaine N.. 2014. Determination of Urinary Creatinine in Washington State Residents via Liquid ChromatographyTandem Mass Spectrometry. International Journal of Analytical Chemistry،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1035929

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

West, Caroline E.& Rhodes, Blaine N.. Determination of Urinary Creatinine in Washington State Residents via Liquid ChromatographyTandem Mass Spectrometry. International Journal of Analytical Chemistry No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-1035929

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

West, Caroline E.& Rhodes, Blaine N.. Determination of Urinary Creatinine in Washington State Residents via Liquid ChromatographyTandem Mass Spectrometry. International Journal of Analytical Chemistry. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1035929

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1035929