Reliability of a Fully Automated Interpretation of γ-H2AX Foci in Lymphocytes of Moderately Trained Subjects under Resting Conditions

المؤلفون المشاركون

Heydenreich, Juliane
Otto, Christoph
Mayer, Frank
Carlsohn, Anja

المصدر

Journal of Nutrition and Metabolism

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-07-23

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

التغذية والحميات

الملخص EN

Background.

Analysis of γ-H2AX foci is a promising approach to evaluate exercise-induced DNA damage.

However, baseline levels and day-to-day variability of γ-H2AX foci have not been investigated in healthy subjects at rest.

Methods.

Blood was taken from eight moderately trained healthy males (29 ± 3 yrs, 1.84 ± 0.03 m, and 85 ± 6 kg) at two separate days (M1/M2) after 24-hour exercise cessation.

Number of γ-H2AX foci per 100 lymphocytes (N), number of foci per affected lymphocyte (NAL), percentage of affected lymphocytes (PAL), and diameter (D) of γ-H2AX foci were analyzed (mean ± SD).

Differences between M1 and M2 were analyzed using paired t-tests (α = 0.05).

Day-to-day variability was evaluated by calculating the coefficients of variation (CV%), bias, and limits of agreement (LoA).

Results.

There were no statistically significant differences between M1 (N: 7.6 ± 4.4, NAL: 1.2 ± 0.2, PAL: 5.9 ± 2.6%, and D: 0.63 ± 0.07) and M2 (N: 8.4 ± 4.6, NAL: 1.3 ± 0.1, PAL: 6.9 ± 4.2%, and D: 0.66 ± 0.06).

CV was calculated to be 98.5% (N), 88.9% (PAL), 11.3% (NAL), and 8.0% (D).

Bias (LoA) was 0.75 (−15.2/13.7), −0.02 (−0.36/0.33), −1.0 (−11.9/9.9), and −0.04 (−0.16/0.09), respectively.

Conclusions.

Background level in healthy subjects is approximately 0.07 to 0.09 γ-H2AX foci/cell.

NAL and D are reliable measures.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Heydenreich, Juliane& Otto, Christoph& Mayer, Frank& Carlsohn, Anja. 2014. Reliability of a Fully Automated Interpretation of γ-H2AX Foci in Lymphocytes of Moderately Trained Subjects under Resting Conditions. Journal of Nutrition and Metabolism،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1042161

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Heydenreich, Juliane…[et al.]. Reliability of a Fully Automated Interpretation of γ-H2AX Foci in Lymphocytes of Moderately Trained Subjects under Resting Conditions. Journal of Nutrition and Metabolism No. 2014 (Dec. 2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1042161

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Heydenreich, Juliane& Otto, Christoph& Mayer, Frank& Carlsohn, Anja. Reliability of a Fully Automated Interpretation of γ-H2AX Foci in Lymphocytes of Moderately Trained Subjects under Resting Conditions. Journal of Nutrition and Metabolism. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1042161

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1042161