Comparison of Anterior Segment Measurements with ScheimpflugPlacido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts

المؤلفون المشاركون

Huang, Jinhai
Liao, Na
Bao, Fangjun
Yu, Ye
Lu, Weicong
Hu, Qingjie
Wang, Qinmei
Savini, G.

المصدر

Journal of Ophthalmology

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-10-23

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To assess the consistency of anterior segment measurements obtained using a Sirius Scheimpflug/Placido photography-based topography system (CSO, Italy) and IOLMaster partial coherence interferometry (Carl Zeiss Meditec, Germany) in eyes with cataracts.

Methods.

A total of 90 eyes of 90 patients were included in this prospective study.

The anterior chamber depth (ACD), keratometry (K), corneal astigmatism axis, and white to white (WTW) values were randomly measured three times with Sirius and IOLMaster.

Concordance between them was assessed by calculating 95% limits of agreement (LoA).

Results.

The ACD and K taken with the Sirius were statistically significantly higher than that taken with the IOLMaster; however, the Sirius significantly underestimated the WTW values compared with the IOLMaster.

Good agreement was found for Km and ACD measurements, with 95% LoA of −0.20 to 0.54 mm and −0.16 to 0.34 mm, respectively.

Poor agreement was observed for astigmatism axis and WTW measurements, as the 95% LoA was −23.96 to 23.36° and −1.15 to 0.37 mm, respectively.

Conclusion.

With the exception of astigmatism axis and WTW, anterior segment measurements taken by Sirius and IOLMaster devices showed good agreement and may be used interchangeably in patients with cataracts.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Huang, Jinhai& Liao, Na& Savini, G.& Bao, Fangjun& Yu, Ye& Lu, Weicong…[et al.]. 2014. Comparison of Anterior Segment Measurements with ScheimpflugPlacido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts. Journal of Ophthalmology،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1042574

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Huang, Jinhai…[et al.]. Comparison of Anterior Segment Measurements with ScheimpflugPlacido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts. Journal of Ophthalmology No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-1042574

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Huang, Jinhai& Liao, Na& Savini, G.& Bao, Fangjun& Yu, Ye& Lu, Weicong…[et al.]. Comparison of Anterior Segment Measurements with ScheimpflugPlacido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts. Journal of Ophthalmology. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1042574

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1042574