Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography

المؤلفون المشاركون

Lee, David A.
Blieden, Lauren S.
Baker, Laura A.
Rigi, Mohammed
Nguyen, Donna
Feldman, Robert M.
Mankiewicz, Kimberly A.
Bell, Nicholas P.
Chuang, Alice Z.

المصدر

Journal of Ophthalmology

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-08-19

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To introduce a new anterior segment optical coherence tomography parameter, trabecular-iris circumference volume (TICV), which measures the integrated volume of the peripheral angle, and establish a reference range in normal, open angle eyes.

Methods.

One eye of each participant with open angles and a normal anterior segment was imaged using 3D mode by the CASIA SS-1000 (Tomey, Nagoya, Japan).

Trabecular-iris space area (TISA) and TICV at 500 and 750 µm were calculated.

Analysis of covariance was performed to examine the effect of age and its interaction with spherical equivalent.

Results.

The study included 100 participants with a mean age of 50 (±15) years (range 20–79).

TICV showed a normal distribution with a mean (±SD) value of 4.75 µL (±2.30) for TICV500 and a mean (±SD) value of 8.90 µL (±3.88) for TICV750.

Overall, TICV showed an age-related reduction ( P = 0.035 ) .

In addition, angle volume increased with increased myopia for all age groups, except for those older than 65 years.

Conclusions.

This study introduces a new parameter to measure peripheral angle volume, TICV, with age-adjusted normal ranges for open angle eyes.

Further investigation is warranted to determine the clinical utility of this new parameter.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rigi, Mohammed& Blieden, Lauren S.& Nguyen, Donna& Chuang, Alice Z.& Baker, Laura A.& Bell, Nicholas P.…[et al.]. 2014. Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography. Journal of Ophthalmology،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1042584

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rigi, Mohammed…[et al.]. Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography. Journal of Ophthalmology No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-1042584

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rigi, Mohammed& Blieden, Lauren S.& Nguyen, Donna& Chuang, Alice Z.& Baker, Laura A.& Bell, Nicholas P.…[et al.]. Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography. Journal of Ophthalmology. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1042584

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1042584