Simulation of Electron Energy Spectra of a Biased Paracentric Hemispherical Deflection Analyzer as a Function of Entry Bias: Effects of Misalignments

المؤلف

Sise, O.

المصدر

Journal of Spectroscopy

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-04-16

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الفيزياء

الملخص EN

The performance of a biased paracentric hemispherical deflection analyzer (HDA), including fringing fields and their effect on focusing and energy resolution, is investigated using numerical methods.

Electron energy spectra are calculated for three entry positions R 0 = 84 mm, 100 mm, and 112 mm and compared with the recent experimental measurements.

In both experiment and calculation, the two different paracentric entry positions R 0 = 84 mm and R 0 = 112 mm, on either side of the mean radius of 100 mm, are found to have a base energy resolution of about two times better than the conventional centric entry position R 0 = 100 mm.

In order to explain the discrepancies (6–30%) between the simulated and the experimental resolutions the focusing characteristics are further investigated for different displacements of the input lens ( Δ R 0 ) with respect to the entry position R 0 and the tilted input beam axis by α shift in the dispersive direction.

We have found that the blame does not in fact lie with the theory and we have shown that the input lens may have been misaligned in the experiment.

Slight misalignments affect both the true energy resolution measurement and the transmission of the beam.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Sise, O.. 2014. Simulation of Electron Energy Spectra of a Biased Paracentric Hemispherical Deflection Analyzer as a Function of Entry Bias: Effects of Misalignments. Journal of Spectroscopy،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1043073

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Sise, O.. Simulation of Electron Energy Spectra of a Biased Paracentric Hemispherical Deflection Analyzer as a Function of Entry Bias: Effects of Misalignments. Journal of Spectroscopy No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-1043073

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Sise, O.. Simulation of Electron Energy Spectra of a Biased Paracentric Hemispherical Deflection Analyzer as a Function of Entry Bias: Effects of Misalignments. Journal of Spectroscopy. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1043073

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1043073