The Mass Attenuation Coefficients, Electronic, Atomic, and Molecular Cross Sections, Effective Atomic Numbers, and Electron Densities for Compounds of Some Biomedically Important Elements at 59.5 keV
المؤلفون المشاركون
Akça, Burcu
Erzeneoğlu, Salih Z.
المصدر
Science and Technology of Nuclear Installations
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-11-11
دولة النشر
مصر
عدد الصفحات
8
الملخص EN
The mass attenuation coefficients for compounds of biomedically important some elements (Na, Mg, Al, Ca, and Fe) have been measured by using an extremely narrow collimated-beam transmission method in the energy 59.5 keV.
Total electronic, atomic, and molecular cross sections, effective atomic numbers, and electron densities have been obtained by using these results.
Gamma-rays of 241Am passed through compounds have been detected by a high-resolution Si(Li) detector and by using energy dispersive X-ray fluorescence spectrometer (EDXRF).
Obtained results have been compared with theoretically calculated values of WinXCom and FFAST.
The relative difference between the experimental and theoretical values are −9.4% to +11.9% with WinXCom and −11.8% to +11.7% FFAST.
Results have been presented and discussed in this paper.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Akça, Burcu& Erzeneoğlu, Salih Z.. 2014. The Mass Attenuation Coefficients, Electronic, Atomic, and Molecular Cross Sections, Effective Atomic Numbers, and Electron Densities for Compounds of Some Biomedically Important Elements at 59.5 keV. Science and Technology of Nuclear Installations،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1047792
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Akça, Burcu& Erzeneoğlu, Salih Z.. The Mass Attenuation Coefficients, Electronic, Atomic, and Molecular Cross Sections, Effective Atomic Numbers, and Electron Densities for Compounds of Some Biomedically Important Elements at 59.5 keV. Science and Technology of Nuclear Installations No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-1047792
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Akça, Burcu& Erzeneoğlu, Salih Z.. The Mass Attenuation Coefficients, Electronic, Atomic, and Molecular Cross Sections, Effective Atomic Numbers, and Electron Densities for Compounds of Some Biomedically Important Elements at 59.5 keV. Science and Technology of Nuclear Installations. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-1047792
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1047792
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر