Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures

المؤلفون المشاركون

Nemec, Patrik
Smitka, Martin
Malcho, Milan

المصدر

The Scientific World Journal

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-05-18

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري
تكنولوجيا المعلومات وعلم الحاسوب

الملخص EN

Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems.

The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser.

One of the most important parts of the LHP is the porous wick structure.

The wick structure provides capillary force to circulate the working fluid.

To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected.

The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes.

For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used.

Analysis of these porous structures and LHP design are described in the paper.

And the measurements’ influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Nemec, Patrik& Smitka, Martin& Malcho, Milan. 2014. Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures. The Scientific World Journal،Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-1050781

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Nemec, Patrik…[et al.]. Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures. The Scientific World Journal No. 2014 (2014), pp.1-9.
https://search.emarefa.net/detail/BIM-1050781

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Nemec, Patrik& Smitka, Martin& Malcho, Milan. Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures. The Scientific World Journal. 2014. Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-1050781

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1050781