Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load

المؤلفون المشاركون

Li, Qing Wei
Yao, Gui Huan

المصدر

Advances in Materials Science and Engineering

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-03-03

دولة النشر

مصر

عدد الصفحات

11

الملخص EN

A soft sensor for oxide scales on the steam side of superheater tubes of utility boiler under uneven circumferential loading is proposed for the first time.

First finite volume method is employed to simulate oxide scales growth temperature on the steam side of superheater tube.

Then appropriate time and spatial intervals are selected to calculate oxide scales thickness along the circumferential direction.

On the basis of the oxide scale thickness, the stress of oxide scales is calculated by the finite element method.

At last, the oxide scale thickness and stress sensors are established on support vector machine (SMV) optimized by particle swarm optimization (PSO) with time and circumferential angles as inputs and oxide scale thickness and stress as outputs.

Temperature and stress calculation methods are validated by the operation data and experimental data, respectively.

The soft sensor is applied to the superheater tubes of some power plant.

Results show that the soft sensor can give enough accurate results for oxide scale thickness and stress in reasonable time.

The forecasting model provides a convenient way for the research of the oxide scale failure.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Li, Qing Wei& Yao, Gui Huan. 2015. Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load. Advances in Materials Science and Engineering،Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1053151

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Li, Qing Wei& Yao, Gui Huan. Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load. Advances in Materials Science and Engineering No. 2015 (2015), pp.1-11.
https://search.emarefa.net/detail/BIM-1053151

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Li, Qing Wei& Yao, Gui Huan. Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load. Advances in Materials Science and Engineering. 2015. Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1053151