Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery

المؤلفون المشاركون

Sultan, Pervez
Soltanifar, Daniel
Bogod, David
Harrison, Sally
Carvalho, Brendan

المصدر

Anesthesiology Research and Practice

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-03-10

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Background.

There is no consensus on the optimum management of failed tracheal intubation in emergency cesarean delivery performed for fetal compromise.

The decision making process on whether to wake the patient or continue anesthesia with a supraglottic airway device is an underexplored area.

This survey explores perceptions and experiences of obstetric anesthetists managing failed intubation.

Methods.

Anesthetists attending the Group of Obstetric Anaesthetists London (GOAL) Meeting in April 2014 were surveyed.

Results.

Ninety-three percent of anesthetists surveyed would not always wake the patient in the event of failed intubation for emergency cesarean delivery performed for fetal compromise.

The median (interquartile range) of perceived acceptability of continuing anesthesia with a well-fitting supraglottic airway device, assessed using a visual analogue scale (0–100; 0 completely unacceptable; 100 completely acceptable), was 90 [22.5].

Preoperative patient consent regarding the use of a supraglottic airway device for surgery in the event of failed intubation would affect the decision making of 40% of anaesthetists surveyed.

Conclusion.

These results demonstrate that a significant body of anesthetists with a subspecialty interest in obstetric anesthesia in the UK would not always wake up the patient and would continue with anesthesia and surgery with a supraglottic airway device in this setting.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Soltanifar, Daniel& Bogod, David& Harrison, Sally& Carvalho, Brendan& Sultan, Pervez. 2015. Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery. Anesthesiology Research and Practice،Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1053942

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Soltanifar, Daniel…[et al.]. Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery. Anesthesiology Research and Practice No. 2015 (2015), pp.1-7.
https://search.emarefa.net/detail/BIM-1053942

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Soltanifar, Daniel& Bogod, David& Harrison, Sally& Carvalho, Brendan& Sultan, Pervez. Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery. Anesthesiology Research and Practice. 2015. Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1053942

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1053942