Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement

المؤلفون المشاركون

Greene, Nathaniel H.
Cobb, Benjamin G.
Linnau, Ken F.
Kent, Christopher D.

المصدر

Anesthesiology Research and Practice

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-01-01

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Background.

Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist.

Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter.

Methods.

This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD) on computed tomography (CT) to determine loss of resistance depth acquired during epidural placement.

Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging.

Results.

There was a strong association between CT measurement and loss of resistance depth ( P < 0.0001 ); the presence of morbid obesity ( BMI > 35 ) changed this relationship ( P = 0.007 ).

The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs > 0.9 ).

Conclusions.

Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter.

Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Greene, Nathaniel H.& Cobb, Benjamin G.& Linnau, Ken F.& Kent, Christopher D.. 2015. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement. Anesthesiology Research and Practice،Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1053949

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Greene, Nathaniel H.…[et al.]. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement. Anesthesiology Research and Practice No. 2015 (2015), pp.1-6.
https://search.emarefa.net/detail/BIM-1053949

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Greene, Nathaniel H.& Cobb, Benjamin G.& Linnau, Ken F.& Kent, Christopher D.. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement. Anesthesiology Research and Practice. 2015. Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1053949

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1053949