Frequency of Electrolyte Derangement after Transurethral Resection of Prostate: Need for Postoperative Electrolyte Monitoring
المؤلفون المشاركون
المصدر
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-05-18
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Objective.
To determine the electrolyte derangement following transurethral resection of prostate (TURP).
Methods.
All patients undergoing TURP from June 2012 to April 2013 were included.
Preoperative electrolytes were performed within a week of procedures.
Monopolar TURP using 1.5% glycine was performed.
Serum Na+ and K+ were assessed within 1 hour postoperatively and subsequently if clinically indicated.
Results.
The study included 280 patients.
Sixty-six patients (23.6%) had electrolyte derangement after TURP.
Patients with deranged electrolytes were older (mean age of 73.41 ± 4.08 yrs.
versus 68.93 yrs.
± 10.34) and had a longer mean resection time (42.5 ± 20.04 min versus 28.34 ± 14.64 min).
Mean weight of tissue resected (41.49 ± 34.46 g versus 15.33 ± 9.74 g) and volume of irrigant used (23.55 ± 15.20 L versus 12.81 ± 7.57 L) were also significantly higher in patients with deranged electrolytes (all p=0.00).
On multivariate logistic regression analysis preoperative sodium level was found to be a significant predictor of postoperative electrolyte derangement (odds ratio 0.267, S.E.
= 0.376, and p value = 0.00).
Conclusion.
Electrolyte derangement occurs in older patients, with larger amount of tissue and longer time of resection and higher volume of irrigant, and in those with lower serum preoperative sodium levels.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Aziz, Wajahat& Ather, M. Hammad. 2015. Frequency of Electrolyte Derangement after Transurethral Resection of Prostate: Need for Postoperative Electrolyte Monitoring. Advances in Urology،Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1053986
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Aziz, Wajahat& Ather, M. Hammad. Frequency of Electrolyte Derangement after Transurethral Resection of Prostate: Need for Postoperative Electrolyte Monitoring. Advances in Urology No. 2015 (2015), pp.1-5.
https://search.emarefa.net/detail/BIM-1053986
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Aziz, Wajahat& Ather, M. Hammad. Frequency of Electrolyte Derangement after Transurethral Resection of Prostate: Need for Postoperative Electrolyte Monitoring. Advances in Urology. 2015. Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1053986
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1053986
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر