![](/images/graphics-bg.png)
Measurement of the Physical Properties during Laparoscopic Surgery Performed on Pigs by Using Forceps with Pressure Sensors
المؤلفون المشاركون
Osaka, Kimito
Makiyama, Kazuhide
Yamanaka, Hiroyuki
Nagasaka, Manabu
Ogata, Masato
Yamada, Takahiro
Kubota, Yoshinobu
المصدر
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-10، 10ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-02-17
دولة النشر
مصر
عدد الصفحات
10
التخصصات الرئيسية
الملخص EN
Objectives.
Here we developed a unique training system, a patient specific virtual reality simulator, for laparoscopic renal surgery.
To develop the simulator, it was important to first identify the physical properties of the organ.
Methods.
We recorded the force measured during laparoscopic surgery performed on pigs by using forceps with pressure sensors.
Several sensors, including strain gauges, accelerometers, and a potentiometer, are attached to the forceps.
Results.
Throughout the experiment, we measured the reaction force in response to the forceps movement in real time.
Conclusions.
The experiment showed the possibility of digitizing these physical properties in humans as well.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Yamanaka, Hiroyuki& Makiyama, Kazuhide& Osaka, Kimito& Nagasaka, Manabu& Ogata, Masato& Yamada, Takahiro…[et al.]. 2015. Measurement of the Physical Properties during Laparoscopic Surgery Performed on Pigs by Using Forceps with Pressure Sensors. Advances in Urology،Vol. 2015, no. 2015, pp.1-10.
https://search.emarefa.net/detail/BIM-1053993
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Yamanaka, Hiroyuki…[et al.]. Measurement of the Physical Properties during Laparoscopic Surgery Performed on Pigs by Using Forceps with Pressure Sensors. Advances in Urology No. 2015 (2015), pp.1-10.
https://search.emarefa.net/detail/BIM-1053993
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Yamanaka, Hiroyuki& Makiyama, Kazuhide& Osaka, Kimito& Nagasaka, Manabu& Ogata, Masato& Yamada, Takahiro…[et al.]. Measurement of the Physical Properties during Laparoscopic Surgery Performed on Pigs by Using Forceps with Pressure Sensors. Advances in Urology. 2015. Vol. 2015, no. 2015, pp.1-10.
https://search.emarefa.net/detail/BIM-1053993
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1053993
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)