Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T

المؤلفون المشاركون

Han, Paul Kyu
Park, Sung-Hong
Kim, Seong-Gi
Ye, Jong Chul

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-24، 24ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-08-27

دولة النشر

مصر

عدد الصفحات

24

التخصصات الرئيسية

الطب البشري

الملخص EN

Conventional functional magnetic resonance imaging (fMRI) technique known as gradient-recalled echo (GRE) echo-planar imaging (EPI) is sensitive to image distortion and degradation caused by local magnetic field inhomogeneity at high magnetic fields.

Non-EPI sequences such as spoiled gradient echo and balanced steady-state free precession (bSSFP) have been proposed as an alternative high-resolution fMRI technique; however, the temporal resolution of these sequences is lower than the typically used GRE-EPI fMRI.

One potential approach to improve the temporal resolution is to use compressed sensing (CS).

In this study, we tested the feasibility of k-t FOCUSS—one of the high performance CS algorithms for dynamic MRI—for non-EPI fMRI at 9.4T using the model of rat somatosensory stimulation.

To optimize the performance of CS reconstruction, different sampling patterns and k-t FOCUSS variations were investigated.

Experimental results show that an optimized k-t FOCUSS algorithm with acceleration by a factor of 4 works well for non-EPI fMRI at high field under various statistical criteria, which confirms that a combination of CS and a non-EPI sequence may be a good solution for high-resolution fMRI at high fields.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Han, Paul Kyu& Park, Sung-Hong& Kim, Seong-Gi& Ye, Jong Chul. 2015. Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T. BioMed Research International،Vol. 2015, no. 2015, pp.1-24.
https://search.emarefa.net/detail/BIM-1054300

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Han, Paul Kyu…[et al.]. Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T. BioMed Research International No. 2015 (2015), pp.1-24.
https://search.emarefa.net/detail/BIM-1054300

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Han, Paul Kyu& Park, Sung-Hong& Kim, Seong-Gi& Ye, Jong Chul. Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-24.
https://search.emarefa.net/detail/BIM-1054300

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1054300