Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

المؤلفون المشاركون

Venail, Frederic
Mura, Thibault
Mathiolon, Caroline
Menjot de Champfleur, Sophie
Piron, Jean Pierre
Sicard, Marielle
Sterkers-Artieres, Françoise
Mondain, Michel
Uziel, Alain
Akkari, Mohamed

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-07-05

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

الطب البشري

الملخص EN

The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency.

It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement), electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons.

The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users.

In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device).

The electrical response, measured using auto-NRT (neural responses telemetry) algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above.

NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P < 0.01 ), the scalar placement of the electrodes (β = −8.50 ± 1.97, P < 0.01 ), and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF).

Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Venail, Frederic& Mura, Thibault& Akkari, Mohamed& Mathiolon, Caroline& Menjot de Champfleur, Sophie& Piron, Jean Pierre…[et al.]. 2015. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants. BioMed Research International،Vol. 2015, no. 2015, pp.1-10.
https://search.emarefa.net/detail/BIM-1055313

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Venail, Frederic…[et al.]. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants. BioMed Research International No. 2015 (2015), pp.1-10.
https://search.emarefa.net/detail/BIM-1055313

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Venail, Frederic& Mura, Thibault& Akkari, Mohamed& Mathiolon, Caroline& Menjot de Champfleur, Sophie& Piron, Jean Pierre…[et al.]. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-10.
https://search.emarefa.net/detail/BIM-1055313

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1055313