Environmental Stability and Residual Stresses in Zirconia Femoral Head for Total Hip Arthroplasty: In Vitro Aging versus Retrieval Studies

المؤلفون المشاركون

Takahashi, Yasuhito
Masaoka, Toshinori
Pezzotti, Giuseppe
Shishido, Takaaki
Yamamoto, Kengo
Arita, Masanori
Sano, Keiji

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-06-03

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

The objective of this study was to compare the low temperature degradation (LTD) behavior of femoral heads made of 3Y-TZP as observed on retrievals with that induced in vitro upon prolonged exposures to a hydrothermal environment.

The time-dependent evolution of tetragonal-to-monoclinic transformation and the related residual stresses were nondestructively monitored by Raman microspectroscopy.

An increasing intensification of tensile and compressive stresses was detected with increasing hydrothermal aging duration in tetragonal and monoclinic phases, respectively.

The dependence of monoclinic fraction upon exposure time was rationalized through the Mehl-Avrami-Johnson (MAJ) formalism in order to interpret the LTD process according to a two-step mechanism of formation and growth of monoclinic nuclei.

In vitro results were compared to in vivo monoclinic contents in the same type of 3Y-TZP head retrievals after implantation periods of 1.6–16.6 y, also including literature data previously reported by other authors.

One-hour exposure under the selected aging condition is estimated to correspond to in vivo exposures of 4 and 2 years according to ISO and ASTM criteria, respectively.

A critical review of these two criteria according to the present analyses revealed that the ASTM simulation predicts more closely the in vivo results as compared to the ISO one.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Arita, Masanori& Takahashi, Yasuhito& Pezzotti, Giuseppe& Shishido, Takaaki& Masaoka, Toshinori& Sano, Keiji…[et al.]. 2015. Environmental Stability and Residual Stresses in Zirconia Femoral Head for Total Hip Arthroplasty: In Vitro Aging versus Retrieval Studies. BioMed Research International،Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1056232

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Arita, Masanori…[et al.]. Environmental Stability and Residual Stresses in Zirconia Femoral Head for Total Hip Arthroplasty: In Vitro Aging versus Retrieval Studies. BioMed Research International No. 2015 (2015), pp.1-9.
https://search.emarefa.net/detail/BIM-1056232

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Arita, Masanori& Takahashi, Yasuhito& Pezzotti, Giuseppe& Shishido, Takaaki& Masaoka, Toshinori& Sano, Keiji…[et al.]. Environmental Stability and Residual Stresses in Zirconia Femoral Head for Total Hip Arthroplasty: In Vitro Aging versus Retrieval Studies. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1056232

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل