Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy

المؤلفون المشاركون

Hirata, Hideki
Yoshidome, Satoshi
Nakamura, Katsumasa
Shioyama, Yoshiyuki
Atsumi, Kazushige
Nakamura, Yasuhiko
Yoshikawa, Hideki
Nishikawa, Kei
Arimura, Hidetaka

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-01-05

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

Objective.

To investigate the feasibility of an automated framework for estimating the lung tumor locations for tumor-based patient positioning with megavolt-cone-beam computed tomography (MV-CBCT) during stereotactic body radiotherapy (SBRT).

Methods.

A lung screening phantom and ten lung cancer cases with solid lung tumors, who were treated with SBRT, were employed to this study.

The locations of tumors in MV-CBCT images were estimated using a tumor-template matching technique between a tumor template and the MV-CBCT.

Tumor templates were produced by cropping the gross tumor volume (GTV) regions, which were enhanced by a Sobel filter or a blob structure enhancement (BSE) filter.

Reference tumor locations (grand truth) were determined based on a consensus between a radiation oncologist and a medical physicist.

Results.

According to the results of the phantom study, the average Euclidean distances of the location errors in the original, Sobel-filtered, and BSE-filtered images were 2.0 ± 4.1 mm, 12.8 ± 9.4 mm, and 0.4 ± 0.5 mm, respectively.

For clinical cases, these were 3.4 ± 7.1 mm, 7.2 ± 11.6 mm, and 1.6 ± 1.2 mm, respectively.

Conclusion.

The feasibility study suggests that our proposed framework based on the BSE filter may be a useful tool for tumor-based patient positioning in SBRT.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yoshidome, Satoshi& Arimura, Hidetaka& Nakamura, Katsumasa& Shioyama, Yoshiyuki& Atsumi, Kazushige& Nakamura, Yasuhiko…[et al.]. 2015. Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy. BioMed Research International،Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1056305

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yoshidome, Satoshi…[et al.]. Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy. BioMed Research International No. 2015 (2015), pp.1-9.
https://search.emarefa.net/detail/BIM-1056305

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yoshidome, Satoshi& Arimura, Hidetaka& Nakamura, Katsumasa& Shioyama, Yoshiyuki& Atsumi, Kazushige& Nakamura, Yasuhiko…[et al.]. Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1056305

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1056305