A Method to Improve Electron Density Measurement of Cone-Beam CT Using Dual Energy Technique

المؤلفون المشاركون

Men, Kuo
Dai, Jian-Rong
Li, Ming-Hui
Chen, Xin-Yuan
Zhang, Ke
Tian, Yuan
Huang, Peng
Xu, Ying-Jie

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-08-05

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To develop a dual energy imaging method to improve the accuracy of electron density measurement with a cone-beam CT (CBCT) device.

Materials and Methods.

The imaging system is the XVI CBCT system on Elekta Synergy linac.

Projection data were acquired with the high and low energy X-ray, respectively, to set up a basis material decomposition model.

Virtual phantom simulation and phantoms experiments were carried out for quantitative evaluation of the method.

Phantoms were also scanned twice with the high and low energy X-ray, respectively.

The data were decomposed into projections of the two basis material coefficients according to the model set up earlier.

The two sets of decomposed projections were used to reconstruct CBCT images of the basis material coefficients.

Then, the images of electron densities were calculated with these CBCT images.

Results.

The difference between the calculated and theoretical values was within 2% and the correlation coefficient of them was about 1.0.

The dual energy imaging method obtained more accurate electron density values and reduced the beam hardening artifacts obviously.

Conclusion.

A novel dual energy CBCT imaging method to calculate the electron densities was developed.

It can acquire more accurate values and provide a platform potentially for dose calculation.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Men, Kuo& Dai, Jian-Rong& Li, Ming-Hui& Chen, Xin-Yuan& Zhang, Ke& Tian, Yuan…[et al.]. 2015. A Method to Improve Electron Density Measurement of Cone-Beam CT Using Dual Energy Technique. BioMed Research International،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057036

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Men, Kuo…[et al.]. A Method to Improve Electron Density Measurement of Cone-Beam CT Using Dual Energy Technique. BioMed Research International No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1057036

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Men, Kuo& Dai, Jian-Rong& Li, Ming-Hui& Chen, Xin-Yuan& Zhang, Ke& Tian, Yuan…[et al.]. A Method to Improve Electron Density Measurement of Cone-Beam CT Using Dual Energy Technique. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057036

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1057036